Peerless Industries SF 16D manual Cc Dd, Installation to Solid Concrete or Cinder Block

Page 6

Installation to Solid Concrete or Cinder Block

WARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica- tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard- ware and components.

1

Make sure that wall plate (AA) is level, use it as a

template to mark four mounting holes. The top

mounting hole should be 2.5" above the desired screen center as shown in figure 1.1 on page 4. Drill four 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (DD) in holes flush with wall as shown (right). Place wall plate over anchors and secure with #14 x 2.5" screws (CC). Level, then tighten all fasteners.

WARNING

Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

Never tighten in excess of 80 in. • lb (9 N.M.).

WARNING

Always attach concrete expansion anchors directly to load-bearing concrete.

Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing mate- rial. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer.

1

concrete

 

 

surface

 

 

DD

Drill holes and insert anchors (DD).

2

AA

 

CC DD

Place plate (AA) over anchors (DD) and secure with screws (CC).

3

Tighten all fasteners.

AA

DD

CC

 

 

 

INCORRECT

VIEW

wall

concrete

plate

 

 

 

CUTAWAY

 

plaster/

 

dry wall

 

 

CORRECT

wall plate

concrete

 

plaster/

 

drywall

6 of 9

ISSUED: 08-02-05 SHEET #: 202-9010-1

Image 6
Contents Models SF 16D Features Tools Needed for Assembly AccessoriesTable of Contents Parts List Installation to Single Wood Stud Wall Skip to onInstallation to Double Wood Stud Wall Installation to Solid Concrete or Cinder Block CC DDInstalling Interface Bracket to PLP Adapter Plate 1landscape portraitInstalling Interface Bracket to LC Adapter Plate Mounting and Removing Flat Panel Screen Detail