Peerless Industries SA730P-S Tension Adjustment, Nylock NUT Snap CAP Socket, Slot, Socket Screw

Page 9

NOTE: Adjustment points (socket screws) are factory torqued for optimal performance. This factory torque setting is recommended to prevent the screen from slipping over time. If more or less tension is desired follow this optional step. You may not achieve optimal torque value if factory torque settings are adjusted.

If more or less tension is desired in tilt mechanism, remove snap caps as shown in detail 3. Insert a flat head screw-

5driver into slot and pry cap away from tilt mechanism. To adjust tilt, tighten or loosen socket screw no more than half a turn using 5 mm allen wrench (G). To adjust roll, tighten or loosen 10-32 nylock nut.

WARNING

Do not remove screw or loosen screw until it is no longer engaged with the mount. Doing so may cause the screen to fall.

If screws become loose over time, tighten screws as necessary. Tighten screws to 50 in. • lb (5.6 N.M.) maximum torque.

10-32 NYLOCK NUT

SNAP CAP

SOCKET

SCREW

SLOT

DETAIL 3

Tension Adjustment

6If more or less tension is desired in the arm pivot points, do the following:

To increase tension, turn tension screw(s) clockwise using 5 mm allen wrenchs (G). NOTE: Tighten screws to 50 in. • lb (5.6 N.M.) maximum torque.

To reduce tension, turn tension screw(s) couter-clockwise using 5 mm allen wrenchs (G). NOTE: Do not loosen more than half a turn.

SOCKET SCREW

SOCKET SCREW

9 of 29

ISSUED: 05-09-05 SHEET #: 095-9224-9 12-05-09

© 2009 Peerless Industries, Inc. All rights reserved. Peerless is a registered trademark of Peerless Industries, Inc.

All other brand and product names are trademarks or registered trademarks of their respective owners.

Image 9
Contents Features Table of Contents Tools Needed for AssemblyLA-100 LA-100S SA730P SA730P-S Description Qty Parts ListInstallation to Wood Stud Wall StudWall Plate CS = Center of Screen Wood Stud Wall Solid Concrete Cinder Block Wall Plate Installation to Solid Concrete and Cinder BlockOr E For Vesa For VESA100 Mounting PatternAdapter Plate Cord Cord ManagementDetail Nylock NUT Snap CAP Socket Tension AdjustmentSlot Socket ScrewCaracterísticas Contenido Herramientas necesarias para el ensamblajeEspañol Construcción DE LA Pared Accesorios NecesariosEspañol 12 de Lista de piezasMontantes Pared CON Montantes DE Madera Instalación en una pared con montantes de maderaPlaca DE Apoyo Placa DE Pared CS = Centro DE LA Pantalla 13 de14 de Vesa EN EL Caso DE LA Configuración DE Montaje DEPlaca Adaptadora 15 deManejo de cables Cables L16 de Cables Ranura L Cord17 de Nota No lo gire más de media vuelta Ajuste Tensor del BrazoTornillo DE Cabeza Hueca 18 deCaractéristiques Table des matières Outils nécessaires au montageFrançais Type DE MUR Pièces DE Fixation RequisesFrançais 21 sur LA-100 LA-100S SA730P SA730P-S Description Qté Nº de pièceInstallation sur un mur à montant en bois Montant22 sur 23 sur Bloc DE Béton Pleinbéton DE Mâchefer Plaque MuralePour UNE Disposition DE Montage Vesa MD Ou EPlaque ’ADAPTATION 24 surGestion des câbles Câble L25 sur Câble Fente Câbles26 sur Réglage de la tension du bras Mm G. Remarque Ne tournez pas de plus d’un demi-tour27 sur Limited FIVE-YEAR Warranty Garantie DE Cinq ANS