Peerless Industries SA730P-S, D-LA-100S manual Installation to Solid Concrete and Cinder Block

Page 5

Installation to Solid Concrete and Cinder Block

WARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard- ware and components.

Use a level to draw a vertical line on mounting

1 surface. Level and use wall plate as template to mark center of holes. The top mounting hole should be located 3.25" (83 mm) above the desired screen center as shown in figure 1.1 on page 4. Drill two 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (B) in holes flush with wall as shown right. Place wall arm (A) over anchors and secure with two #14 x 2.5" flat head wood screws (C) using #3 phillips screwdrive bit (M) as shown in figures 1.3. Make sure wall arm is level, and tighten all fasteners.

Insert two fastener caps (I) into wall plate mounting holes.

WARNING

Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

Never tighten in excess of 80 in. • lb (9 N.M.).

Always attach concrete expansion anchors directly to load-bearing concrete.

Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable (not evaluated by UL), the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).

VIEW

INCORRECT

CORRECT

concrete

wall

concrete

 

wall

plate

 

 

plate

 

CUTAWAY

 

 

plaster/

 

plaster/

 

drywall

 

drywall

1

concrete

surface

B

Drill holes and insert anchors (B).

2

A

 

 

C

B

Place plate (A) over anchors (B) and secure with screws (C).

3

Tighten all fasteners.

SOLID CONCRETE

CINDER

BLOCK

B

WALL PLATE

C

I

A

fig. 1.3

5 of 29

ISSUED: 05-09-05 SHEET #: 095-9224-9 12-05-09

Image 5
Contents Features Table of Contents Tools Needed for AssemblyLA-100 LA-100S SA730P SA730P-S Description Qty Parts ListWall Plate CS = Center of Screen Wood Stud Wall Installation to Wood Stud WallStud Solid Concrete Cinder Block Wall Plate Installation to Solid Concrete and Cinder BlockAdapter Plate Or EFor Vesa For VESA100 Mounting Pattern Cord Cord ManagementDetail Nylock NUT Snap CAP Socket Tension AdjustmentSlot Socket ScrewCaracterísticas Contenido Herramientas necesarias para el ensamblajeEspañol Construcción DE LA Pared Accesorios NecesariosEspañol 12 de Lista de piezasMontantes Pared CON Montantes DE Madera Instalación en una pared con montantes de maderaPlaca DE Apoyo Placa DE Pared CS = Centro DE LA Pantalla 13 de14 de Vesa EN EL Caso DE LA Configuración DE Montaje DEPlaca Adaptadora 15 de16 de Manejo de cablesCables L 17 de CablesRanura L Cord Nota No lo gire más de media vuelta Ajuste Tensor del BrazoTornillo DE Cabeza Hueca 18 deCaractéristiques Table des matières Outils nécessaires au montageFrançais Type DE MUR Pièces DE Fixation RequisesFrançais 21 sur LA-100 LA-100S SA730P SA730P-S Description Qté Nº de pièce22 sur Installation sur un mur à montant en boisMontant 23 sur Bloc DE Béton Pleinbéton DE Mâchefer Plaque MuralePour UNE Disposition DE Montage Vesa MD Ou EPlaque ’ADAPTATION 24 sur25 sur Gestion des câblesCâble L 26 sur CâbleFente Câbles 27 sur Réglage de la tension du brasMm G. Remarque Ne tournez pas de plus d’un demi-tour Limited FIVE-YEAR Warranty Garantie DE Cinq ANS