ADVANCED MENU

Vbatt Calibration

14.1 V

 

0.0 V

EXIT NEXT

-

+

RTS Compensation*

ADVANCED MENU

RTS Compensation

A 14.1 V

F 13.8V

EXIT NEXT WIDE

ADVANCED MENU

RTS Compensation

A 14.1 V

F 13.8 V

EXIT NEXT LIMIT SET

RTS COMPENSATION

 

Upper LIMIT G

14.1

V

Lower LIMIT

13.2

V

BACK

- +

 

A quality calibrated voltmeter will provide even more accurate FLEXmax 80 battery readings if an undesirable voltage drop occurs. When measuring battery voltage, ensure a good connection is made to the four wire lugs. Check the battery temperature compensation voltages if the voltages are much different than you expect from the charger setup Absorb and Float voltage settings. Use the <->and <+> soft keys to match the readings from the voltmeter (use of appropriate wire gauge will mini- mize voltage drop). When finished, press the <NEXT> soft key to view the RTS Compensation screen.

During cold weather, a battery often requires a higher recharging voltage. Lower quality inverters might not accommodate these higher voltages and can shut down during recharging, cutting off power to their loads. The FLEXmax 80 allows the user to lower the compensated voltage in the Absorb cycle so these inverters will remain operating. Also, some batteries have an absolute voltage limit that should not be exceeded and the WIDE/LMIT option allows the user to control this during recharging. WIDE allows the RTS full control over recharging; LIMIT sets the ceiling and floor voltages for the RTS.

During hot weather, the LIMIT feature set point assures recharging will continue at a high enough voltage rather than dropping too low in reaction to a higher ambient temperature. This assures the recharging voltage ad- equately charges, but should be monitored according to the battery manufacturer’s recommendations.

The RTS default compensated voltages apply if the WIDE/ LIMIT option is set to WIDE. To change these values, press the <WIDE> soft key to bring up the next screen which

allows user-determined limits. Press the <SET> soft key to adjust these values.

Press the < > soft key to choose the limit value you want to adjust. Press the < - > and < + > soft keys to adjust the chosen value(s). When finished, press the <BACK> soft key to return to the RTS Compensation screen.

*Optional OutBack RTS must be installed

50

Image 51
Contents User’s Guide Dear OutBack Customer Warranty SummaryContact Information About OutBack Power SystemsDisclaimer Date and RevisionTable of Contents Product Registration and Optional Extended Warranty Firmware FLEXmax 80 Maximum Power Point Tracking Charge ControllerScope IntroductionStandards and Requirements Personal Precautions During Installation Outback Power Systems FLEXmax Installing the FLEXmax 80 FLEXware DC Enclosures Mounting to PlywoodDC Enclosure FLEXmax Bushing Locknut Conduit Nipple Determining Wire Sizes Wire and Disconnect SizingOpen Circuit Voltage/Wire and Disconnect Size FLEXmax 80 wiring compartment FLEXmax 80 Wiring ConnectionsPage Page Page Soft keys How to Read the FLEXmax 80 Screen DiagramsPowering Up Power Up ScreenOutBack12V Power Systems FLEXmax 150 Password ContrasenaSelect Version Elija la Version USA Next Enter Entra SELUSA Noyes Sytem VoltageEnter AUX OFF Status ScreenEnd of Day Summary Screen Recharging Using the PV ArrayAccessing the Main Menu Charger Aux Light EQ Misc Advanced Logging StatsExit F G GO Absorbing 14.4V Float 13.8V Charger Set-UpCurrent Limit 80.0ANight Light Output Off AUX Mode and Its FunctionsAUX Mode Exit Next SET ModePressing the Next soft key scrolls through the AUX functions AUX Mode Menu PathAUX modes in order of appearance on the FLEXmax 80 display Exitvolt Vent FAN Volts Programming the AUX ModesOff Vent FanFan screen Exit VoltExit Next SET PV Trigger Output OffExit Time Volt Output OnPV Trigger Exit Time Volt PV VoltsPress the Next soft key to view the Error Output screen Hold Time Sec 01.1 Back +PV Trigger Output On Error Output 01 hrs Exitvolt Error LOW Batt VoltsExitvolt AUX Mode Error Output Exit Next SET Mode AUX Mode Exit Hyst Time VoltBack + OFF Press the Volt soft key Night Light Off Hysteresis Time Minutes Back +Night Light On Time Hours Back + Night Light Threshold Voltage 010 Back +Press the Next soft key ro view the AUX Float screen Output Off AutoFloat Output Off Diversion Relay Output OffAbsorb--Float--EQ Relative Volts Hold Delay 01.0 Time SecondsBack DLY+ AUX Mode Diversion RelayPress the Exit soft key Exit Time Volt AUX ModeDiversion Solid St Output On Example of DiversionDiversion Load and AUX Wiring Set-Up Illustrated Delay Time Sec Timer Back + Press the Time and Volt soft keys to adjust the set pointsLow Batt Disconnect Exit Time Volt Disconnect Volts BackRE-CONNECT Volts Exit soft key twice to return to the Main Menu Off screen Remote Output OffCharger GAux Light Misc Logging StatsCharger Aux GLight EQ Misc Optimize Logging Stats EQ-Battery EqualizeExit + Mode BacklightBack Auto Start Stop Battery EqualizeExit Next -EQV +EQV Battery Equalize Exit Next -HRS +HRS Battery EqualizeExit Next -EQV +EQV Count000 Exit DAY +DAYPress Next to Continue to the Force Bulk/Float Screen MISC-MiscellaneousGT State PWM% ChgT 255 07 50.0 Exit NextPCB PWM%Force Exit Next Float BulkExit Advanced Menu Snooze Mode .6 ampAdvanced Charger Aux Light Misc GAdvanced Logging StatsPress the Next soft key to view the Park Mpp screen Wakeup Mode 1.5V 05m Exit Next +VOC +MinMppt Mode Auto Track Exit Next nonGT Mode This screen allows the user to choose one of these modesPark Mpp Watts 77 % Voc Park Mpp 77 % VocExit Next -% +% Advanced Menu Mpp Range Limit %Voc Min Max Exit Next 1/2 90%Charging-Related Screens Advanced Menu Absorb Time Limits HoursExit Next + 12.6 00 aExit Next Limit SET RTS Compensation Vbatt Calibration 14.1RTS Compensation 14.1 Exit Next Wide Advanced MenuExit Next Limit SET Mode Exit Next Mode Advanced MenuMode Exit Next Mode RTS Compensation 14.4 V FExit Next Mode Advanced Menu Reset to Defaults?Aux Polarity GLogging Stats Are you sure? Reset to DefaultsYesno Advanced Menu ChargerMIN FLT LoggingClear LOG Back Totl Daily Today 0000Ah 00.0 KWH 011Vp 00.0Ap 00kWp MAXStats Secondary Stats screen Micro-Hydro and Fuel Cell Applications Warranty its use in these applicationsPark Mpp Watts Mppt Mode Auto TrackTo adjust the Lower Mpp Range Limit Advanced Menu Micro-Hydro and Fuel Cell ApplicationsAbbreviated Menu Map Positive grounded systems OutBack Power System GTFX/GVFX Grid-tie settingsApplication Notes Grid-tie applications non-OutBack inverter/chargers24V Battery System Efficiency Curve 12V Battery System Efficiency CurveUnderstanding the Various Operational Modes Page Page Aux relay state indicates if the AUX is on or OFF MATE-Displayed FLEXmax 80 Screens Status Mode ScreensMATE-Displayed FLEXmax 80 Status Meter Screens FLEXmax Meter ScreensPress Setp to view Setpoint screens MATE-Displayed FLEXmax 80 Status Setpt SET Point Screen MATE-Displayed FLEXmax 80 Advanced ScreensCC Setpoint Screens FLEXmax 80 Advanced Menu FLEXmax 80 Stats Screens FLEXmax 80 EQ ScreensFLEXmax 80 AUX Screens FLEXmax 80 Displayed ScreensAbbreviated Exit Next + Advanced Menu FLEXmax 80 is always Sleeping Troubleshooting GuideFLEXmax 80 does not boot/power-up blank LCD FLEXmax 80 not producing expected powerFLEXmax 80 is not equalizing FLEXmax 80 Battery Temperature Compensated VoltageTo enable/open the FLEXmax Select Version screens FLEXmax 80 Internal FanFLEXmax 80 is beeping Typical Array Sizing Guide Standard vs. Australian Default Settings 36V PV Array 48v Vmp Wire Distance Chart12V PV Array 16v Vmp 24V PV Array 32v Vmp48V PV Array 64v Vmp 60V PV Array 80v Vmp72V PV Array 96v Vmp NEC Compliance Wire and Disconnect SizingBattery Side of the Controller PV Side of the ControllerOutput Rating less than 64 amps Wiring CompartmentMaximum recommended battery conductor is #2** AWG Recommended Conductor and Breaker Sizes for the FLEXmaxFLEXmax 80 MULTI-STAGE Battery Charging Page Non-Battery Temperature Compensated System Battery Temperature Compensated SystemBattery temperature compensation with other slopes Battery Voltage and State of Charge Suggested Battery Charger SET PointsCalling the Factory for Assistance SpecificationsFLEXmax Products Five Year Limited Warranty InformationRevision.2007-10-02 Outback Power Systems Inc 19009 62nd Ave. NE Limited Warranty RegistrationEU Declaration of Conformity OWNER’S System Information Phone +1 BARCELONA, España Phone +34.93.654.9568