28. STANDARD vs. AUSTRALIAN DEFAULT SETTINGS
The Australian version FLEXmax 80 has a few default settings that differ from the Standard version default settings. However, there are no differences in performance and efficiency between the two versions. The Standard and Australian version can be identified as follows:
OutBack | 12V | OutBack | 12V |
| Power | Power | Systems |
| Systems | FLEXmax | |
FLEXmax 80 |
|
|
Standard Version | Australian Version |
Below are a few default setting differences between the Standard and Australian version.
Settings | Standard | Australian | ||
Charger | Absorb | Float | Absorb | Float |
12V | 14.4V | 13.6V | 14.4V | 13.8V |
24V | 28.8V | 27.2V | 28.8V | 27.6V |
36V | 43.2V | 40.8V | 43.2V | 41.4V |
48V | 57.6V | 54.4V | 57.6V | 55.2V |
60V | 72.0V | 68.0V | 72.0V | 69.0V |
Equalize | Equalize Volts | Equalize Volts |
12V | 14.4 | 14.7 |
24V | 28.8 | 29.4 |
36V | 43.2 | 44.1 |
48V | 57.6 | 58.8 |
60V | 72.0 | 73.5 |
Equalize Time | 01 Hours | 03 Hours |
76