Outback Power Systems 80 user manual Limited Warranty Registration

Page 89

maxT M 80

Limited Warranty Registration

Complete this form to request a Limited

Warranty, and return it to:

Outback Power Systems Inc.

19009 62nd Ave. NE

Arlington, WA 98223

NOTE: A Limited Warranty Certificate will only be issued if this Registration Card is received by OutBack within 90 days of the date of the first retail sale of the eligible Product. Please submit a copy (not the original) of the Product purchase invoice, which confirms the date and location of purchase, the price paid, and the Product Model and Serial Number.

Five Year Limited FLEXmax Warranty Registration

System Owner

Name:_ _______________________________

Country: _______________________________

Address:_______________________________

Telephone Number:______________________

City, State, Zip Code: _____________________

E-mail_________________________________

Product

Product Model Number:_ _________________

Sold by:________________________________

Product Serial Number:___________________

Purchase Date:___________________________

Optional Extended Warranty* Coverage? (circle one): Yes

No

Please circle the three most important factors affecting your purchase decision:

Price

Product Reputation

Product Features

Reputation of OutBack Power Systems

Value

 

System

 

 

 

 

System Install/Commission Date:_ ______________

Number of FLEXmax Products in System:___________

FLEXmax Charging Source(i.e. Solar):_____________

System Array Size: ____________________________

System Array Nominal Voltage: _________________

Type of PV Modules:___________________________

DC Input Wiring Size and Length:_ ______________

System Battery Bank Size (Amp Hours):_ ___________

Type of Batteries:____________________________

 

 

 

Installer

 

 

 

 

Installer:_______________________________

Contractor Number:_ ______________________

Installer Address: ________________________

Installer City, State, Zip:_ ____________________

Installer E-mail:_________________________

 

 

 

*Extended Warranty

OutBack Power Systems offers an optional five(5) year extension to the standard five(5) year Limited Warranty in North America for the FLEXmax 80 product. To request a 5-year Limited Warranty extension for a total effective warranty coverage period of ten(10) years; include a check or money order in the amount of $250USD payable to OutBack Power Systems, Inc. along with your Warranty Registration.

Revision.2007-10-02

88

Image 89
Contents User’s Guide Dear OutBack Customer Warranty SummaryDisclaimer About OutBack Power SystemsDate and Revision Contact InformationTable of Contents Product Registration and Optional Extended Warranty Scope FLEXmax 80 Maximum Power Point Tracking Charge ControllerIntroduction FirmwareStandards and Requirements Personal Precautions During Installation Outback Power Systems FLEXmax DC Enclosure FLEXmax Bushing Locknut Conduit Nipple Installing the FLEXmax 80 FLEXware DC EnclosuresMounting to Plywood Open Circuit Voltage/Wire and Disconnect Size Determining Wire SizesWire and Disconnect Sizing FLEXmax 80 wiring compartment FLEXmax 80 Wiring ConnectionsPage Page Page Soft keys How to Read the FLEXmax 80 Screen DiagramsOutBack12V Power Systems FLEXmax Powering UpPower Up Screen Select Version Elija la Version Password ContrasenaUSA Next Enter Entra SEL 150Enter USA NoyesSytem Voltage AUX OFF Status ScreenEnd of Day Summary Screen Recharging Using the PV ArrayExit F G GO Accessing the Main MenuCharger Aux Light EQ Misc Advanced Logging Stats Current Limit Charger Set-Up80.0A Absorbing 14.4V Float 13.8VAUX Mode AUX Mode and Its FunctionsExit Next SET Mode Night Light Output OffPressing the Next soft key scrolls through the AUX functions AUX Mode Menu PathAUX modes in order of appearance on the FLEXmax 80 display Off Programming the AUX ModesVent Fan Exitvolt Vent FAN VoltsExit Next SET Exit VoltPV Trigger Output Off Fan screenPV Trigger Output OnExit Time Volt PV Volts Exit Time VoltPV Trigger Output On Press the Next soft key to view the Error Output screenHold Time Sec 01.1 Back + Exitvolt AUX Mode Error Output Error Output 01 hrsExitvolt Error LOW Batt Volts Back + OFF Exit Next SET Mode AUX ModeExit Hyst Time Volt Night Light On Time Hours Back + Night Light Off Hysteresis Time Minutes Back +Night Light Threshold Voltage 010 Back + Press the Volt soft keyFloat Output Off Output Off AutoDiversion Relay Output Off Press the Next soft key ro view the AUX Float screenBack DLY+ AUX Mode Hold Delay 01.0 Time SecondsDiversion Relay Absorb--Float--EQ Relative VoltsDiversion Solid St Output On Exit Time Volt AUX ModeExample of Diversion Press the Exit soft keyDiversion Load and AUX Wiring Set-Up Illustrated Low Batt Disconnect Delay Time Sec Timer Back +Press the Time and Volt soft keys to adjust the set points RE-CONNECT Volts Exit Time Volt Disconnect VoltsBack Charger GAux Light Misc Remote Output OffLogging Stats Exit soft key twice to return to the Main Menu Off screenExit + Mode EQ-Battery EqualizeBacklight Charger Aux GLight EQ Misc Optimize Logging StatsExit Next -EQV +EQV Battery Equalize Battery EqualizeExit Next -HRS +HRS Battery Equalize Back Auto Start Stop000 CountExit DAY +DAY Exit Next -EQV +EQVGT State PWM% ChgT 255 07 50.0 MISC-MiscellaneousExit Next Press Next to Continue to the Force Bulk/Float ScreenForce PWM%Exit Next Float Bulk PCBAdvanced Snooze Mode .6 ampCharger Aux Light Misc GAdvanced Logging Stats Exit Advanced MenuMppt Mode Auto Track Exit Next nonGT Mode Wakeup Mode 1.5V 05m Exit Next +VOC +MinThis screen allows the user to choose one of these modes Press the Next soft key to view the Park Mpp screenExit Next -% +% Advanced Menu Park Mpp 77 % VocMpp Range Limit %Voc Min Max Exit Next 1/2 90% Park Mpp Watts 77 % VocExit Next + Charging-Related ScreensAdvanced Menu Absorb Time Limits Hours 12.6 00 aRTS Compensation 14.1 Vbatt Calibration 14.1Exit Next Wide Advanced Menu Exit Next Limit SET RTS CompensationMode Exit Next Mode Mode Exit Next Mode Advanced MenuRTS Compensation 14.4 V F Exit Next Limit SETAux Polarity Exit Next Mode Advanced MenuReset to Defaults? Yesno Advanced Menu Are you sure? Reset to DefaultsCharger GLogging StatsClear LOG Back Totl Daily LoggingToday 0000Ah 00.0 KWH 011Vp 00.0Ap 00kWp MAX MIN FLTStats Secondary Stats screen Micro-Hydro and Fuel Cell Applications Warranty its use in these applicationsTo adjust the Lower Mpp Range Limit Mppt Mode Auto TrackAdvanced Menu Micro-Hydro and Fuel Cell Applications Park Mpp WattsAbbreviated Menu Map Application Notes OutBack Power System GTFX/GVFX Grid-tie settingsGrid-tie applications non-OutBack inverter/chargers Positive grounded systems24V Battery System Efficiency Curve 12V Battery System Efficiency CurveUnderstanding the Various Operational Modes Page Page Aux relay state indicates if the AUX is on or OFF MATE-Displayed FLEXmax 80 Screens Status Mode ScreensPress Setp to view Setpoint screens MATE-Displayed FLEXmax 80 Status Meter ScreensFLEXmax Meter Screens CC Setpoint Screens MATE-Displayed FLEXmax 80 Status Setpt SET Point ScreenMATE-Displayed FLEXmax 80 Advanced Screens FLEXmax 80 Advanced Menu FLEXmax 80 AUX Screens FLEXmax 80 EQ ScreensFLEXmax 80 Displayed Screens FLEXmax 80 Stats ScreensAbbreviated Exit Next + Advanced Menu FLEXmax 80 does not boot/power-up blank LCD Troubleshooting GuideFLEXmax 80 not producing expected power FLEXmax 80 is always SleepingFLEXmax 80 is not equalizing FLEXmax 80 Battery Temperature Compensated VoltageFLEXmax 80 is beeping To enable/open the FLEXmax Select Version screensFLEXmax 80 Internal Fan Typical Array Sizing Guide Standard vs. Australian Default Settings 12V PV Array 16v Vmp Wire Distance Chart24V PV Array 32v Vmp 36V PV Array 48v Vmp72V PV Array 96v Vmp 48V PV Array 64v Vmp60V PV Array 80v Vmp Battery Side of the Controller Wire and Disconnect SizingPV Side of the Controller NEC ComplianceMaximum recommended battery conductor is #2** AWG Wiring CompartmentRecommended Conductor and Breaker Sizes for the FLEXmax Output Rating less than 64 ampsFLEXmax 80 MULTI-STAGE Battery Charging Page Battery temperature compensation with other slopes Non-Battery Temperature Compensated SystemBattery Temperature Compensated System Battery Voltage and State of Charge Suggested Battery Charger SET PointsCalling the Factory for Assistance SpecificationsFLEXmax Products Five Year Limited Warranty InformationRevision.2007-10-02 Outback Power Systems Inc 19009 62nd Ave. NE Limited Warranty RegistrationEU Declaration of Conformity OWNER’S System Information Phone +1 BARCELONA, España Phone +34.93.654.9568