2.Screw the fan tray to the rear of the chassis using the included screws.

Install the Switch Blade

¾¾ To install a switch blade in a M6100 series chassis switch:

1.Select a slot for the switch blade.

2.Remove a blank front panel from the chassis slot, if necessary.

Any unoccupied switch blade slot in the chassis must have a blank faceplate installed to ensure satisfactory protection from EMI and to maintain adequate airflow through the chassis.

3.Remove the switch blade from the antistatic packaging.

CAUTION:  To prevent ESD damage, hold the switch blade by the metal rail and front panel only. Never touch the components on the PCB or the pins on any of the connectors.

4.Verify that the switch blade injector-ejector handles are open.

5.Keep the injector-ejector handles in the open position as you slide the switch blade into the chassis slot.

CAUTION:  Do not slide the switch blade into the open chassis slot if the injector-ejector handles are in the latched position.

7

Image 7
Contents Netgear ProSAFE M6100 Chassis Switch InstallationContents M6100 Series Front Panels Before Installing the Switch Blade ¾¾ To bracket-mount the chassis Install the Chassis¾¾ To install the fan tray Install the Fan TrayInstall the Switch Blade Page ¾¾ To install the power supply Install the Power Supply¾¾ To install the optional PoE XCM89P or UPoE XCM89UP board Install Optional PoE XCM89P or UPoE XCM89UP BoardConfigure the Switch Blade Computer in Dhcp Client Mode Without a Dhcp Server Computer with a Static IP Address ¾¾ To configure the switchData bits Parity. None Stop bit Flow control. None Page Computer in Dhcp Client Mode with a Dhcp Server Data bits Parity. None Stop bit Flow control. None Page Page Technical Support