Step 5
Initialize the lift system:
•Connect the motor cable to the control box and “pigtail” on the lift column as shown in figures A and B.
•Connect the IR receiver/control switch and control box power as shown in figures C and D.
•Once all the cables are properly connected, the lift must be initialized by pressing and holding the down button on the IR receiver until the column is at its lowest limit (see figure E for IR receiver orientation). There will be slight raising and lowering of the lift.
•Release the down button momentarily before depressing it again for 2 seconds. There will again be a slight movement of the lift, this means the lift is initialized and all previous settings erased.
Set the upper limit
•Press and hold the up button until the desired top limit is reached, release the up button and depress the down button to stop the lift and set the upper limit. If you want maximum extension, hold the up key until the lift is fully extended and stops before releasing.
•The settings will now function when the mechanism is opperated by remote control.
In order to reset the programming, disconnect power to the unit and repeat the above steps.
Figure A
6 |
Figure C
6 |
Figure D
6 |
Figure E
IR
UP
DWN
12