HYDRAULIC INSTALLATION
Keep hands and body away from pressurized lines. Use paper or cardboard, not hands or other body parts to check for leaks. Wear safety goggles. Hydraulic fluid under pressure can easily penetrate skin and will cause serious injury or death.
Make sure that all operating and service person- nel know that if hydraulic fluid penetrates skin, it must be surgically removed as soon as possible by a doctor familiar with this form of injury or gan- grene, serious injury, or death will result. CON-
TACT A PHYSICIAN IMMEDIATELY IF FLUID ENTERS SKIN OR EYES. DO NOT DELAY.
Make sure all hydraulic hoses, fittings, and valves are in good condition and not leaking before starting power unit or using equipment. Check and route hoses carefully to prevent damage. Hoses must not be twisted, bent sharply, kinked, frayed, pinched, or come into contact with any moving parts. Operate moveable components through full operational range to check clearances. Replace any damaged hoses immediately.
Assemble Bulkhead Bracket
1. | Connect bulkhead adapter (3) to bulkhead | 3. | 1009495 | Adapter, 3/8 NPTM x 9/16 JICF |
| bracket (19) and secure using hex nut provided | 13. | 38604 | Elbow, 9/16 JICM x 9/16 JICF 90° |
| with adapter. | 16. | 64299 | Quick coupler, female 3/8 |
|
| |||
2. | Attach female quick coupler (16) and elbow (13) | 19. | 1022141 | Bulkhead bracket |
| to bulkhead bracket (19) as shown in Figure 17. |
|
|
|
3.Remove lower right bolt from top link bracket.
4.Place bulkhead bracket over top link bracket and secure into position using hardware previously removed. See Figure 17.
DP18
Figure 17. Bulkhead Bracket Installed
DP10
Figure 18. Bulkhead Bracket Assembly