3.XM Kit 256273 only: Remove 3/4 npt plugs from the end of the diaphragm pump fluid manifold and place in center.

4.For only heating hoppers or heating hoppers and heated hose: Install tube fitting (31) in fluid inlet. See FIG. 7.

5.For heating heated hose only (see FIG. 7):

a.Install elbow (32), mounting fitting (23), o-ring (22) and 1.5 gallon reservoir tank (21) on dia- phragm pump fluid inlet.

b.XM Kit 256273 only: Connect elbow fitting (7) to mounting fitting (23).

6.Install bushing (12) and elbow tube fitting (17) to diaphragm pump fluid outlet. See FIG. 7.

Installation

7.Mount diaphragm pump to bracket.

XM Kit 256273 only: Use four screws (2) to mount pump (3) on mounting bracket. See FIG. 7.

XP Kit 24M224 only: Use nuts (135) to mount pump (3) to threads on mounting bracket. See FIG. 7.

8.Connect air regulator assembly.

XM Kit 256273 only: Connect nipple (10), air regu- lator/gauge (9), and fitting (19) to pump (3). See FIG. 7.

XP Kit 24M224 only: Connect elbow (137), nipple (10), air regulator/gauge (9), elbow (136), and fitting (19) to pump (3).

9.Remove plug on system air control supply and con- nect fitting (19) in place of the plug. Connect hose (27) between fitting (19) on 100 psi (0.7 MPa, 7 bar) XM air supply and fitting (19) on the air regula- tor/gauge (9). See FIG. 7. Refer to Husky 716 man- ual 308981 if needed.

NOTE: The air regulator (9) controls pump pressure.

XM: Heated Hose Only

 

 

 

XM: All Others

 

 

 

 

 

 

12

17

 

 

19

 

 

 

 

9

 

 

 

 

 

 

 

 

21

 

 

 

 

12

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

17

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

23

 

 

19

 

 

 

 

 

 

 

7

 

 

9

 

 

 

 

 

 

31

 

 

 

 

 

 

 

 

 

33

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

 

 

3

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ti19229a

 

 

 

 

 

 

 

 

XP: Heated Hose Only

 

 

 

XP: All Others

 

137

10

9

136,19,27

 

 

137

10

9

 

 

 

12

 

 

 

 

 

 

17

 

 

136,19,27

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

 

 

 

32

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

33

 

 

 

 

134

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

134

 

 

 

 

 

 

 

 

 

105

 

 

 

105

 

 

 

 

 

 

 

 

 

 

 

 

ti19173a

 

133

135

ti19155a

133

 

 

 

 

135

31

 

 

 

FIG. 7: Diaphragm Pump Installation

313259D

15

Image 15
Contents Hopper or Hose Heat Circulation Kit Important Safety InstructionsRelated Manuals ContentsFire and Explosion Hazard Skin Injection Hazard Single Hose Assembly Dual Hose Assembly Heated Hopper or Hose Circulation KitSingle Hose Assemblies Dual Hose Assemblies Hazardous Location HeatersNon-hazardous Location Heaters Heated Hopper or Hose Circulation Kit 313259D Heat Only Hoppers Configuration Key Typical InstallationBack-Mounted Hoppers BM Side-Mounted Hoppers SMBM Hoppers SM Hoppers Section Tubing Hoppers and Heated Hose Configuration Key Fluid schematic for heating hoppers and heated hose Heated Water Fluid Flow Heated Hose Only Configuration KeySingle Hose Shown Fluid schematic for heated hoseGrounding InstallationXM Heated Hose Only XM All Others XM Kit For heating hoppers only For heating heated hose onlyFor heating hoppers and heated hose Operation Problem Cause Solution MaintenanceTroubleshooting Do not overfill when using oil. See overfilling notice onParts 256273, XM Heated Hopper or Hose Circulation KitFor heating hoppers and heated hose 30 29 Hose only Heater and Diaphragm Pump 3 ConnectionsFor heating heated hose only For heating hoppers or hoppers and heatedRing Part Description Qty24M224, XP Heated Hopper or Hose Circulation Kit Hose Identification Technical Data Technical Data 313259D Graco Information Graco Standard Warranty