Installation

10.Slide Viscon HP heater (A) into slots on frame. Tighten bolts to secure to frame.

XM Kit 256273

A

r_256273_313259_7

XP Kit 24M224

A

ti19156a

All wiring must be done by a qualified electrician. See warnings, page 3.

13.

Wire Viscon HP heater (B) to your voltage supply.

 

Follow wiring procedure in the Viscon HP manual

 

309524.

14.

If heating hoppers:

 

a. Remove bottom plug (P) from hopper (C).

11.For heating hoppers or heating hoppers and heated hose: install fitting (18) and elbow (17) in the heater’s fluid inlet facing away from the system. Install elbow (7) in heater outlet facing the back of the system.

7

18

17

r_256273_313259_16a

FIG. 8

12.For heating heated hose only: connect elbow fit- ting (17) to heater fluid inlet facing the back of the system. Install elbow (7) in the heater outlet facing upward.

17

r_256273_313259_17a

FIG. 9

b.

XP Kit 24M224 only: Install nipple (33) and

 

coupling (139) into bottom of hopper. See

 

page 24.

c.

Install elbows (32) and fittings (31).

d.

Repeat for second hopper.

XM shown

C

P

7 11

P

3132

r_256273_313259_8

15.Remove side plug (P) used for fluid inlet.

16.Replace plug with bushing (11) and elbow fitting (7).

17.Cut tubing (4, 16, 29). See Tubing Lengths on page 14.

NOTE:

Fitting nuts may need retightening as the system reaches normal operating temperatures.

16

313259D

Image 16
Contents Important Safety Instructions Hopper or Hose Heat Circulation KitContents Related ManualsFire and Explosion Hazard Skin Injection Hazard Heated Hopper or Hose Circulation Kit Single Hose Assembly Dual Hose AssemblySingle Hose Assemblies Hazardous Location Heaters Dual Hose AssembliesNon-hazardous Location Heaters Heated Hopper or Hose Circulation Kit 313259D Typical Installation Heat Only Hoppers Configuration KeySide-Mounted Hoppers SM Back-Mounted Hoppers BMBM Hoppers SM Hoppers Section Tubing Hoppers and Heated Hose Configuration Key Fluid schematic for heating hoppers and heated hose Heated Hose Only Configuration Key Heated Water Fluid FlowFluid schematic for heated hose Single Hose ShownInstallation GroundingXM Heated Hose Only XM All Others XM Kit For heating heated hose only For heating hoppers onlyFor heating hoppers and heated hose Operation Maintenance TroubleshootingDo not overfill when using oil. See overfilling notice on Problem Cause Solution256273, XM Heated Hopper or Hose Circulation Kit PartsFor heating hoppers and heated hose 30 29 Heater and Diaphragm Pump 3 Connections For heating heated hose onlyFor heating hoppers or hoppers and heated Hose onlyPart Description Qty Ring24M224, XP Heated Hopper or Hose Circulation Kit Hose Identification Technical Data Technical Data 313259D Graco Standard Warranty Graco Information