Graco 24M224(HP), 256273(HM) Maintenance, Troubleshooting, Problem Cause Solution

Page 19

Maintenance

Check double wall hopper heating fluid level monthly. Add fluid as needed.

Do not overfill when using oil. See overfilling notice on page 18.

Maintenance

Follow pump maintenance instructions in Husky 716 diaphragm pump manual 308981.

Follow heater maintenance instructions in Viscon HP manual 309524.

Troubleshooting

Problem

Cause

Solution

 

 

 

 

 

 

Fluid fittings leaking.

Loose fittings.

Tighten fittings after system reaches

 

 

desired temperature.

 

 

 

Hose not heating to desired tempera-

Diaphragm flow rate set too high.

Decrease diaphragm pump flow rate

ture.

 

to 50 cycles/min.

 

 

 

 

Problem with Viscon HP heater.

See troubleshooting in Viscon HP

 

 

heater manual 309524.

 

 

 

Diaphragm pump not operating cor-

 

See troubleshooting in Husky 716

rectly.

 

diaphragm pump manual 308981.

 

 

 

Oil overflowing out vented hopper

Oil level higher than 3 in. (76.2 mm)

Lower oil level to 3 in. (76.2) below

side fill port during startup.

below fill port at room temperature

hopper fill port.

 

and at rest.

 

 

 

 

Hopper not reaching set temperature

Temperature loss in heated hose is

Allow longer heating time. Insulate

when heating fluid hose first.

too much for the heater capacity to

heated hose bundle.

 

compensate for.

 

 

 

 

Air and heating fluid splatter is exiting

Diaphragm in Husky 716 diaphragm

Replace pump diaphragm. See man-

hopper vented fitting.

pump is cracked.

ual 308981 for parts.

 

 

 

313259D

19

Image 19
Contents Hopper or Hose Heat Circulation Kit Important Safety InstructionsRelated Manuals ContentsFire and Explosion Hazard Skin Injection Hazard Heated Hopper or Hose Circulation Kit Single Hose Assembly Dual Hose AssemblySingle Hose Assemblies Hazardous Location Heaters Dual Hose AssembliesNon-hazardous Location Heaters Heated Hopper or Hose Circulation Kit 313259D Heat Only Hoppers Configuration Key Typical InstallationSide-Mounted Hoppers SM Back-Mounted Hoppers BMBM Hoppers SM Hoppers Section Tubing Hoppers and Heated Hose Configuration Key Fluid schematic for heating hoppers and heated hose Heated Water Fluid Flow Heated Hose Only Configuration KeySingle Hose Shown Fluid schematic for heated hoseGrounding InstallationXM Heated Hose Only XM All Others XM Kit For heating heated hose only For heating hoppers onlyFor heating hoppers and heated hose Operation Problem Cause Solution MaintenanceTroubleshooting Do not overfill when using oil. See overfilling notice on256273, XM Heated Hopper or Hose Circulation Kit PartsFor heating hoppers and heated hose 30 29 Hose only Heater and Diaphragm Pump 3 ConnectionsFor heating heated hose only For heating hoppers or hoppers and heatedRing Part Description Qty24M224, XP Heated Hopper or Hose Circulation Kit Hose Identification Technical Data Technical Data 313259D Graco Information Graco Standard Warranty