Graco 256273(HM), 24M224(HP) important safety instructions Operation

Page 18

Operation

Operation

1.Select fluid to use for heating circulation.

50% water and 50% ethylene glycol mixture is recommended for fastest heat-up time and pre- vention of algae build-up regardless of ambient temperature.

Oil can be used but heat-up time will increase and the hopper fill level must be decreased. See item 2.

NOTE:

Detailed diaphragm pump operating instructions are in the Husky 716 diaphragm pump manual 308981.

2.Fill Heating Fluid in double wall hopper (C) outer cavity. See manual 312747 for instructions.

NOTICE

Do not plug top ports. Always have venting fittings installed to prevent outer cavity pressurization. Failure to do so may cause leakage into spray material.

NOTICE

If oil is the heating fluid selected, the maximum oil level must be 3 in. (76.2 mm) below the hopper side port level. A higher fluid level may cause the oil to overflow during initial pump and heater startup.

NOTE:

If using heated hose: each 50 ft. (15.2 m) heated hose section holds approximately 1.25 gal. (4.7 liters) of fluid.

3.Set the flow rate of the circulation fluid by adjusting the pump’s air regulator (9) until the pump cycles about 50 cycles/min. Do not use a higher flow rate as doing so will decrease system heating perfor- mance and pump life. Never exceed the hose’s

95 psi (0.6 MPa, 6.6 bar) maximum working pres- sure rating.

4.Adjust the heater thermostat to the desired circula- tion temperature. The setting at the heater output thermometer should be about 10° F (6° C) higher than the desired paint temperature. Never exceed the hose’s 140° F (60° C) maximum temperature rating.See Viscon HP heater manual 309524 for instructions.

NOTE:

If the hose is not being used for more than one hour, shut off Viscon HP heater and pump to lengthen heater life.

18

313259D

Image 18
Contents Important Safety Instructions Hopper or Hose Heat Circulation KitContents Related ManualsFire and Explosion Hazard Skin Injection Hazard Single Hose Assembly Dual Hose Assembly Heated Hopper or Hose Circulation KitSingle Hose Assemblies Dual Hose Assemblies Hazardous Location HeatersNon-hazardous Location Heaters Heated Hopper or Hose Circulation Kit 313259D Typical Installation Heat Only Hoppers Configuration KeyBack-Mounted Hoppers BM Side-Mounted Hoppers SMBM Hoppers SM Hoppers Section Tubing Hoppers and Heated Hose Configuration Key Fluid schematic for heating hoppers and heated hose Heated Hose Only Configuration Key Heated Water Fluid FlowFluid schematic for heated hose Single Hose ShownInstallation GroundingXM Heated Hose Only XM All Others XM Kit For heating hoppers only For heating heated hose onlyFor heating hoppers and heated hose Operation Do not overfill when using oil. See overfilling notice on MaintenanceTroubleshooting Problem Cause SolutionParts 256273, XM Heated Hopper or Hose Circulation KitFor heating hoppers and heated hose 30 29 For heating hoppers or hoppers and heated Heater and Diaphragm Pump 3 ConnectionsFor heating heated hose only Hose onlyPart Description Qty Ring24M224, XP Heated Hopper or Hose Circulation Kit Hose Identification Technical Data Technical Data 313259D Graco Standard Warranty Graco Information