Leica 762960 manual Stake out function

Page 10

All target points must be vertical or horizontal on the surface of the wall.

The best results are achieved when the intrument is rotated around a fixed point (e.g. the stop bracket is fully extended and the instrument is placed against a wall).

To take the measurement, the minimum/ maximum function can be called up. The minimum value is used for measurements that must be at right-angles to the target; the maximum distance is used for all other measurements.

)Make sure that the first measurement and the distance to be measured are at right angles. Use the minimum/maximum function.

Indirect measurement - determining a distance using 2 auxilliary measurements

See drawing {G}

3x briefly: the symbol is displayed.

The distance to be measured flashes in the symbol. 1x briefly: takes a measurement of the distance

The second distance to be measured flashes in the symbol

1x briefly: takes a measurement of the hori- zontal distance

The result of the function is displayed in the summary row.

If the button is pressed for along time while

measuring a distance, maximum or minimum contin-

EN

uous measuring is activated.

 

Indirect measurement - determining a distance using 3 auxilliary measurements

See drawing {H}

 

4x briefly: the

symbol is displayed.

The distance to be measured flashes in the symbol. 1x briefly: takes a distance measuement

The second distance to be measured flashes in the symbol

1x briefly: takes a horizontal measurement. The third distance to be measured flashes in the symbol

1x briefly: takes a measurement of the distance

The result of the function is displayed in the summary row.

If the button is pressed for along time while measuring a distance, maximum or minimum contin- uous measuring is activated.

Stake out function

This function is helpful when staking out equal distances, e.g in the erection of wooden substruc- tures. See drawing {I}

5x briefly: the symbol is displayed.

A value is displayed in the summary row (default

Leica DISTO™ D2 762960 en

7

Functions

Image 10
Contents Leica Disto D2 Page Page Intended Use Symbols used in this manualSymbols used in this manual Permitted usesResponsibilities OverviewLimits of use KeyboardStart up OperationReference Setting Switching on/offSetting the instrument CLEAR-KeyMeasuring FunctionsIndirect Measurement Volume functionArea function FunctionsStake out function Timer self-triggering Historical memoryAppendix Switching off the beepTechnical Specifications Display NoticesElectromagnetic Compatibility EMC FCC statement applic. in U.SLabelling Laser classificationClass 2 Laser Products Warranty Disposal