Samsung SHR-3010 Connection with PC for Use, Connection with RS-232C, Communication Method

Page 12

DIGITAL VIDEO RECORDER

GB

 

 

GB

 

4

3

 

 

System Connection for Alarm Recording

Connection with PC for Use

<Rear Side Connection Terminal of SHR-3010>

<Outside Product>

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

1

ALARM IN

1

GND

2

ALARM RESET

2

TRIGGER IN

3

ALARM OUT

3

ALARM IN

6

TRIGGER OUT

4

ALARM CANCEL

1

GND

5

ALARM OUT

Alarm recording is a function for recording the input video when an alarm signal is input while a device with alarm output is connected to this unit.

Connect to the corresponding terminals, as the numbers may be different for external devices.

For external devices, if the alarm input (ALARM INPUT) and alarm cancel (ALARM CANCEL) are not available, you can leave them unconnected.

Connection with RS-232C

A. Communication Method

Data Code: ASCII Code

Protocol: 8 bit Data, 1 Stop bit, None Parity

Transmission speed: 4800, 9600, 19200, 38400 bps

B. RS-232C terminal (D-SUB 9 Pin) and Pin specifications

51

96

Pin No

Pin Specifications

 

 

2

TXD (Transmitted Data)

 

 

3

RXD (Received Data)

 

 

5

SG (Signal Ground)

 

 

1, 4, 6~9

NO Connection

 

 

2-3

2-4

Image 12
Contents Digital Video Recorder Important Safety Instructions Digital Video RecorderContents Summary Introduction Characteristics Variously changing numbers of recording fields per secondConvenient retrieval function Power Alarm3Name and Function of Each Part FullRear View Unpacking HDD Addition Mounting HDDMode setup and cable connection InterfaceII. Connection with Other Devices Connection to External Devices Connection with MultiplexerRS-232C terminal D-SUB 9 Pin and Pin specifications Connection with PC for UseConnection with RS-232C Communication MethodRS-485 terminal and Pin specifications Connection with RS-485Code value by key Data Format Samsung ProtocolIII. Basic Method to use 1Booting the System Power OnRecognizing incoming video signal Power Off 2Basic Screen ViewingLive Screen Viewing Playback screen Viewing Menu Enter Change of Settings 3Menu ViewMove to Parent Menu or Menu End Menu Move Example of menu setting in case of changing time Or Down Button so current second is displayedEach menu item 5Record Setup ➃ Disk END Mode① Audio Record ② Picture Quality6Alarm Record Setup ➄ PRE Alarm Time Limit ⑧ Motion Detection ➅ Post Alarm Time Limit ⑨ SET Area & Sensitivity➆ Main Alarm Picture Rate 7Reservation Record Setup SizeLeft MoveSystem Setup Communication Setup System Information Time Range① from Date 2003 Backup Start Date ⑧ Backup Screen ➂ to Date 2003 Backup Finish DateCancel = Stop Scsi HDD2FROM Record Event List Backup by the record event list Overwrite ReferenceIV. Record 1Basic Record Basic Record② Record Stop ① Current Image Record Record Lock Alarm Record Record in Alarm OccurrenceRelease of Alarm Record Record LockReservation Record Setup Reservation Record Cancel4Reservation Record ① CLOCK/DISPLAY Mode Setup ➂ Alarm Event Search ② Record Event Search ➃ Power Event List1Retrieval Menu View Retrieval Menu EnterRetrieval by Date and Time Recorded Data List View Alarm Record Retrieval Power On/Off Status List View 6Basic Playback 7Various Screen View Using JOG/SHUTTLE Play in Various SpeedView by Field VI. Others Backup Product Standards Appearance DrawingHDD VII. Appendices 1Check Points before Call Service Center Trouble Check PointsQuestion Answer AB68-00377A