Samsung SHR-3010 Connection with RS-485, Code value by key, Data Format Samsung Protocol, Others

Page 13

DIGITAL VIDEO RECORDER

GB

 

GB

 

Connection with RS-485

 

 

 

 

 

D. Code value by key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote control is allowed through connection with RS-485 (up to 1.2km).

 

 

 

Function

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6, 7, 8

Byte 9

Response

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Byte 5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. Communication method

 

 

 

 

 

 

 

 

[SET COMMAND]

 

 

 

 

Data transmission method: Start-Stop Synchronized Serial Interface

 

 

 

MENU

0xA0

Src.Addr

Dest.Addr.

0x0A

0x01

0xFF

Check Sum

0x01

 

Protocol: 8 bit Data, 1 Stop bit, None Parity

 

 

 

 

 

SEARCH

0xA0

Src.Addr

Dest.Addr.

0x0A

0x02

0xFF

Check Sum

0x02

 

 

 

 

 

 

SET/STILL

0xA0

Src.Addr

Dest.Addr.

0x0A

0x03

0xFF

Check Sum

0x03

 

Transmission speed: 4800, 9600, 19200, 38400 bpss

 

 

 

 

 

 

 

 

 

 

 

UP

0xA0

Src.Addr

Dest.Addr.

0x0A

0x04

0xFF

Check Sum

0x04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B. RS-485 terminal and Pin specifications

 

 

 

 

 

DOWN

0xA0

Src.Addr

Dest.Addr.

0x0A

0x05

0xFF

Check Sum

0x05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEFT

0xA0

Src.Addr

Dest.Addr.

0x0A

0x06

0xFF

Check Sum

0x06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT

0xA0

Src.Addr

Dest.Addr.

0x0A

0x07

0xFF

Check Sum

0x07

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLAY

0xA0

Src.Addr

Dest.Addr.

0x0A

0x08

0xFF

Check Sum

0x08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STOP

0xA0

Src.Addr

Dest.Addr.

0x0A

0x09

0xFF

Check Sum

0x09

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECORD

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0A

0xFF

Check Sum

0x0A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC LOCK

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0B

0xFF

Check Sum

0x0B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA +

 

 

 

 

 

F.Shuttle 1

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0C

0xFF

Check Sum

0x0C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F.Shuttle 2

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0D

0xFF

Check Sum

0x0D

 

C. Data Format (Samsung Protocol)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F.Shuttle 3

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0E

0xFF

Check Sum

0x0E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(

) : Byte numbers

 

F.Shuttle 4

0xA0

Src.Addr

Dest.Addr.

0x0A

0x0F

0xFF

Check Sum

0x0F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 Byte Fixed

 

F.Shuttle 5

0xA0

Src.Addr

Dest.Addr.

0x0A

0x10

0xFF

Check Sum

0x10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F.Shuttle 6

0xA0

Src.Addr

Dest.Addr.

0x0A

0x11

0xFF

Check Sum

0x11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start Code (A0H)

 

 

 

 

Start Addr.

 

Target Addr.

 

Command

Check Sum

 

F.Shuttle 7

0xA0

Src.Addr

Dest.Addr.

0x0A

0x12

0xFF

Check Sum

0x12

(1)

 

 

 

(1)

 

 

 

 

(1)

 

(5)

(1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F.Shuttle 8

0xA0

Src.Addr

Dest.Addr.

0x0A

0x13

0xFF

Check Sum

0x13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R.Shuttle 1

0xA0

Src.Addr

Dest.Addr.

0x0A

0x14

0xFF

Check Sum

0x14

Data Byte

 

 

 

 

 

Type

 

Contents

 

Remarks

 

R.Shuttle 2

0xA0

Src.Addr

Dest.Addr.

0x0A

0x15

0xFF

Check Sum

0x15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R.Shuttle 3

0xA0

Src.Addr

Dest.Addr.

0x0A

0x16

0xFF

Check Sum

0x16

 

Byte 1

 

 

Start Code

 

0xA0

 

Start of Data Packet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R.Shuttle 4

0xA0

Src.Addr

Dest.Addr.

0x0A

0x17

0xFF

Check Sum

0x17

 

Byte 2

 

Sender Addr.

 

Transmission Address

 

Source Range (0x00 ~ 0xFF)

 

 

 

 

 

R.Shuttle 5

0xA0

Src.Addr

Dest.Addr.

0x0A

0x18

0xFF

Check Sum

0x18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 3

 

 

Target Addr.

 

Reception Address

 

Destination Range (0x00 ~ 0xFF)

 

 

 

 

 

 

R.Shuttle 6

0xA0

Src.Addr

Dest.Addr.

0x0A

0x19

0xFF

Check Sum

0x19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Only Image Recorder Command

 

0x0A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R.Shuttle 7

0xA0

Src.Addr

Dest.Addr.

0x0A

0x1A

0xFF

Check Sum

0x1A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Key Function

 

Range (0x01 ~ 0xFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R.Shuttle 8

0xA0

Src.Addr

Dest.Addr.

0x0A

0x1B

0xFF

Check Sum

0x1B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 6

 

 

Command

 

0xFF

 

0xFF

 

 

 

 

 

 

R.JOG

0xA0

Src.Addr

Dest.Addr.

0x0A

0x1C

0xFF

Check Sum

0x1C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0xFF

 

0xFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F.JOG

0xA0

Src.Addr

Dest.Addr.

0x0A

0x1D

0xFF

Check Sum

0x1D

 

Byte 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0xFF

 

0xFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E. Others

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 9

 

 

Check Sum

 

Lower byte of (0xFFFF - (values adding Byte 2 ~ Byte 8))

 

 

 

 

 

 

 

 

 

 

 

 

 

Above data format and transmission speed may be changed depending on future

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

development conditions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PC operates as Master, and Target Set as Slave in transmission/reception of data.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No status other than Set Key Function should be received. Provided, however, that con

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tents recorded in a set should be always received for alarm function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Some delay can be happen due to communication speed).

 

 

2-5

2-6

Image 13
Contents Digital Video Recorder Digital Video Recorder Important Safety InstructionsContents Summary Variously changing numbers of recording fields per second Introduction CharacteristicsConvenient retrieval function Alarm Power3Name and Function of Each Part FullRear View Mounting HDD Unpacking HDD AdditionInterface Mode setup and cable connectionII. Connection with Other Devices Connection with Multiplexer Connection to External DevicesConnection with PC for Use RS-232C terminal D-SUB 9 Pin and Pin specificationsConnection with RS-232C Communication MethodConnection with RS-485 RS-485 terminal and Pin specificationsCode value by key Data Format Samsung ProtocolIII. Basic Method to use Power On 1Booting the SystemRecognizing incoming video signal 2Basic Screen Viewing Power OffLive Screen Viewing Playback screen Viewing 3Menu View Menu Enter Change of SettingsMove to Parent Menu or Menu End Menu Move Or Down Button so current second is displayed Example of menu setting in case of changing timeEach menu item ➃ Disk END Mode 5Record Setup① Audio Record ② Picture Quality6Alarm Record Setup ➅ Post Alarm Time Limit ⑨ SET Area & Sensitivity ➄ PRE Alarm Time Limit ⑧ Motion Detection➆ Main Alarm Picture Rate Size 7Reservation Record SetupLeft MoveSystem Setup Communication Setup Time Range System Information➂ to Date 2003 Backup Finish Date ① from Date 2003 Backup Start Date ⑧ Backup ScreenCancel = Stop Scsi HDD2FROM Record Event List Backup by the record event list Reference OverwriteIV. Record Basic Record 1Basic Record② Record Stop ① Current Image Record Record in Alarm Occurrence Record Lock Alarm RecordRelease of Alarm Record Record LockReservation Record Cancel Reservation Record Setup4Reservation Record ② Record Event Search ➃ Power Event List ① CLOCK/DISPLAY Mode Setup ➂ Alarm Event Search1Retrieval Menu View Retrieval Menu EnterRetrieval by Date and Time Recorded Data List View Alarm Record Retrieval Power On/Off Status List View 6Basic Playback Play in Various Speed 7Various Screen View Using JOG/SHUTTLEView by Field VI. Others Product Standards Appearance Drawing BackupHDD VII. Appendices Trouble Check Points 1Check Points before Call Service CenterQuestion Answer AB68-00377A