Pentair LX-100EZ Heater Connections Dual Thermostat GAS HEATER/HEAT Pump, Electric Heater

Page 13

HEATER CONNECTIONS

DUAL THERMOSTAT GAS HEATER/HEAT PUMP

Inside the heater, connect three 18 AWG wires in parallel with the heater toggle switch or in accordance with the Heater Manufacturer’s instructions.

Do not disconnect or bypass the flow, pressure or high limit switches.

Place the heater toggle switch in the “OFF” position, and set the thermostats to desired pool and spa temperatures.

Run the three wires to low-voltage compartment of LX-100 RF Power/Load Center.

Strip insulation ¼”, and connect to circuit board at GHTR Screw Terminals, in accordance with wiring diagram located inside the LX-100 RF Power/Load Center cover:

Connect “High” of heater thermostat to Terminal #S. Connect “Low” of heater thermostat to Terminal #P. Connect “Common” of heater thermostat to Terminal #C.

SINGLE THERMOSTAT GAS HEATER/HEAT PUMP

Inside the heater, connect two 18 AWG wires in series with the heater circuitry.

Do not disconnect or bypass the flow, pressure or high limit switches.

Place the heater toggle switch in the “ON” position, and set the thermostat to the desired temperature.

Run the two wires to low-voltage compartment of LX-100 RF Power/Load Center.

Strip insulation ¼”, and connect to GHTR Screw Terminals at Terminals #P and #C.

Make a jumper wire and connect Terminals #P and #S together.

ELECTRIC HEATER

For systems which utilize an electric heater, a 20-Amp Relay Kit (model RLYLX) should be added at the LX-100 RF Power/Load Center.

Install RL-LX in accordance with instructions provided, and plug onto circuit board at the EHTR relay socket.

The relay is capable of controlling an electric heater (rated up to 3KVA), or the magnetic contactor of a larger electric heater.

Inside the heater , connect two 14 AWG wires in series with the heater thermostat circuitry. Place the heater toggle switch in the “ON” position, and set the thermostat to the desired temperature.

Run the two wires to the high-voltage compartment of the LX-100 RF Power/Load Center, and connect to LINE1 and LOAD1 terminals of the electric heater relay.

Rev. F 3-26-04

13

P/N 520050

Image 13
Contents Important Notice Installation Manual Important Safety Instructions Introduction Safety Features This page is blank Equipment Location System IncludesRefer for Plumbing Requirements on Recommended Hydraulic SchematicSpa should be at or above the level of the pool Plumbing RequirementsHigh Voltage Wiring General LX-100 RF POWER/LOAD CenterSystem Power Equipment PowerLOW Voltage Cables LOW Voltage WiringReceiver Circuit Board Customizing the Communication Link Receiver Antenna Valve ActuatorsSingle Thermostat GAS HEATER/HEAT Pump Heater Connections Dual Thermostat GAS HEATER/HEAT PumpElectric Heater System Options Automatic Countdown Cycle SPA-SIDE Remote Control Auxiliary Valve Pool CleanerWater Temperature Sensor CP-100 Optional Indoor Controller Using the Crimping ToolSystem START-UP CP-100 Optional Indoor Control Panel LX-100EZ Easytouch POOL-SPA Control System Pool Cleaner Protection Safety Features Heater ProtectionIntroduction HAND-HELD RemoteFilter Pump and Pool Cleaner Time Clocks SPA Service Switch Motorized Valves System Options SPA-SIDE Remote Control Equipment PUSH-BUTTONS #S, #1, #2 and #3 Indoor ControllerHAND-HELD Remote Battery Replacement Maintenance Cleaning the SPAWinterizing the System General TROUBLE-SHOOTINGSymptom Possible Cause Solution RF Trouble Shooting TableRev. F Pentair Pool Products