SYSTEM START-UP

Apply power to the system.

At the LX-100 RF Power/Load Center, verify that the POWER "ON" status light is illuminated, and make sure that all of the Service Switches are in the “AUTO” position.

If the status light is not on, check the 3 amp circuit breaker which is located above the faceplate. If the circuit breaker has tripped (indicated by a white tab), push to reset.

On the Hand-held Remote, press the “SPA” Push-buttonto turn the spa on.

Verify that the Valve Actuators have rotated to spa circulation, the filter pump has been activated and the heater has fired.

Press Push-buttons #A, #B, and #C and check that appropriate equipment is being activated.

At the Intake and Return Valves, flip toggle switch on rear of Actuator(s) between “ON1” and “ON2” positions as necessary so that valves have rotated to pool circulation.

At the LX-100 RF Power/Load Center, verify that the FILTER PUMP Time Clock is operating.

To set the time of day, rotate the dial in a clockwise direction until the hours and minutes line up with the white arrow at eight o’clock position on clock face.

To program daily operating cycle(s), depress the desired number of sections around the perimeter of the dial by pushing towards the center. For each section depressed, the filter pump will operate for 15 minutes.

If the system has a POOL CLEANER Time Clock, verify that it is operating, and check that it also activates the filter pump when the FILTER PUMP Time Clock is not programmed on.

At the LX-100 RF Power/Load Center, slide the SPA Service Switch to “FILL”, “DRAIN” and back to “AUTO” position, and verify that the Valve Actuators are rotating accordingly.

If one of the Valve Actuators is 180 degrees out of phase, flip toggle switch on rear of Actuator between “ON1” and “ON2” position.

At the LX-100 RF Power/Load Center, verify that the filter pump is being activated from the “ON” and “OFF” positions of the FILTER Service Switch.

Verify that the auxiliary equipment is being activated from the “ON” and “OFF” positions of the AUX1, AUX2 and AUX3 Service Switches.

Slide FILTER Service Switch to the “ON” position and the HEATER Service Switch to the “SPA & POOL” position, and verify that the heater has fired.

If the heater doesn’t fire, check the controls inside the heater and also the wiring connections.

At the LX-100 RF Power/Load Center, return the HEATER Service Switch to the “SPA ONLY” position and all the other Service Switches to the “AUTO” position.

Rev. F 3-26-04

19

P/N 520050

Image 19
Contents Important Notice Installation Manual Important Safety Instructions Introduction Safety Features This page is blank Equipment Location System IncludesRefer for Plumbing Requirements on Recommended Hydraulic SchematicSpa should be at or above the level of the pool Plumbing RequirementsEquipment Power LX-100 RF POWER/LOAD CenterHigh Voltage Wiring General System PowerLOW Voltage Cables LOW Voltage WiringReceiver Circuit Board Customizing the Communication Link Receiver Antenna Valve ActuatorsSingle Thermostat GAS HEATER/HEAT Pump Heater Connections Dual Thermostat GAS HEATER/HEAT PumpElectric Heater System Options Automatic Countdown Cycle SPA-SIDE Remote Control Auxiliary Valve Pool CleanerWater Temperature Sensor CP-100 Optional Indoor Controller Using the Crimping ToolSystem START-UP CP-100 Optional Indoor Control Panel LX-100EZ Easytouch POOL-SPA Control System HAND-HELD Remote Safety Features Heater ProtectionPool Cleaner Protection IntroductionFilter Pump and Pool Cleaner Time Clocks SPA Service Switch Motorized Valves System Options SPA-SIDE Remote Control Equipment PUSH-BUTTONS #S, #1, #2 and #3 Indoor ControllerHAND-HELD Remote Battery Replacement Maintenance Cleaning the SPAWinterizing the System General TROUBLE-SHOOTINGSymptom Possible Cause Solution RF Trouble Shooting TableRev. F Pentair Pool Products