SYSTEM START-UP
Apply power to the system.
At the
If the status light is not on, check the 3 amp circuit breaker which is located above the faceplate. If the circuit breaker has tripped (indicated by a white tab), push to reset.
On the
Verify that the Valve Actuators have rotated to spa circulation, the filter pump has been activated and the heater has fired.
Press
At the Intake and Return Valves, flip toggle switch on rear of Actuator(s) between “ON1” and “ON2” positions as necessary so that valves have rotated to pool circulation.
At the
To set the time of day, rotate the dial in a clockwise direction until the hours and minutes line up with the white arrow at eight o’clock position on clock face.
To program daily operating cycle(s), depress the desired number of sections around the perimeter of the dial by pushing towards the center. For each section depressed, the filter pump will operate for 15 minutes.
If the system has a POOL CLEANER Time Clock, verify that it is operating, and check that it also activates the filter pump when the FILTER PUMP Time Clock is not programmed on.
At the
If one of the Valve Actuators is 180 degrees out of phase, flip toggle switch on rear of Actuator between “ON1” and “ON2” position.
At the
Verify that the auxiliary equipment is being activated from the “ON” and “OFF” positions of the AUX1, AUX2 and AUX3 Service Switches.
Slide FILTER Service Switch to the “ON” position and the HEATER Service Switch to the “SPA & POOL” position, and verify that the heater has fired.
If the heater doesn’t fire, check the controls inside the heater and also the wiring connections.
At the