Pentair LX-100EZ owner manual SPA Service Switch

Page 24

SPA Service Switch

For normal system operation, keep this Switch in the “AUTO” position.

The “FILL” and “DRAIN” positions are used when cleaning the spa.

FILTER Service Switch

For normal system operation keep this Switch in the “AUTO” position.

The “OFF” and “ON” positions allow your Pool Serviceperson to override the FILTER PUMP Time Clock without altering the program.

CAUTION

If your system incorporates a POOL CLEANER Time Clock, pump damage will occur if the pool cleaner is activated while the FILTER Service Switch is in the "OFF" position.

AUX1, AUX2 and AUX3 Service Switches

For normal system operation, keep these Switches in the “AUTO” position.

The “OFF” and “ON” positions override the Remote Controls, and provide convenient manual control at the equipment site.

HEATER Switch

The “SPA ONLY” position will enable heating only when the spa is being circulated. The “OFF” position will disable the heater.

The “SPA & POOL” position will enable heating whenever the spa or pool is being circulated.

For Dual Thermostat Heaters: At the heater set pool and spa thermostats to desired temperatures. Verify at the heater that the 3-position “ON/OFF” switch was set to “OFF” during installation.

For Single Thermostat Heaters: To heat the spa only set the spa temperature at the heater and set the LX-100 RF Power/Load Center Heater switch to “SPA ONLY”. If pool heating is desired, it is necessary to turn the heater thermostat down to pool temperature and set the LX-100 RF Power/Load Center Heater switch to “SPA & POOL”.

Verify at the heater that the “ON/OFF” switch was set to “ON” during installation.

PUMP DELAY Status Light

A built-in electronic delay circuit will automatically run the filter pump for an additional 4 minutes whenever the spa is turned off. This enables the heater to cool down, so that the heat exchanger and plumbing are not damaged from overheating. (See Heater Protection page 22.)

The PUMP DELAY Light indicates that the delay is in effect.

POWER ON Status Light

Indicates that power has been connected to the system.

If this light is not on, consult your Pool Serviceperson.

P/N 520050

24

Rev. F 3-26-04

Image 24
Contents Important Notice Installation Manual Important Safety Instructions Introduction Safety Features This page is blank System Includes Equipment LocationRecommended Hydraulic Schematic Refer for Plumbing Requirements onPlumbing Requirements Spa should be at or above the level of the poolLX-100 RF POWER/LOAD Center High Voltage Wiring GeneralSystem Power Equipment PowerLOW Voltage Wiring LOW Voltage CablesReceiver Circuit Board Customizing the Communication Link Valve Actuators Receiver AntennaHeater Connections Dual Thermostat GAS HEATER/HEAT Pump Single Thermostat GAS HEATER/HEAT PumpElectric Heater System Options Automatic Countdown Cycle SPA-SIDE Remote Control Pool Cleaner Auxiliary ValveWater Temperature Sensor Using the Crimping Tool CP-100 Optional Indoor ControllerSystem START-UP CP-100 Optional Indoor Control Panel LX-100EZ Easytouch POOL-SPA Control System Safety Features Heater Protection Pool Cleaner ProtectionIntroduction HAND-HELD RemoteFilter Pump and Pool Cleaner Time Clocks SPA Service Switch Motorized Valves System Options SPA-SIDE Remote Control Indoor Controller Equipment PUSH-BUTTONS #S, #1, #2 and #3Maintenance Cleaning the SPA HAND-HELD Remote Battery ReplacementWinterizing the System TROUBLE-SHOOTING GeneralRF Trouble Shooting Table Symptom Possible Cause SolutionRev. F Pentair Pool Products