Section I. Installation Instructions
A.PG2000 RETROFIT INSTRUCTIONS Using The X-10 Remote Control
NOTE:
If an
DANGER
Risk of Electrical Shock or Electrocution.
Always disconnect the power to the PG2000 at the circuit breaker before removing the lid and servicing the light. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock.
1.Turn power switch and colorwheel switch on the side of the PG2000 unit to their “OFF” positions and disconnect power at the circuit breaker.
2.Remove the PG2000 cover by removing the bottom screws.
3.If retrofitting an RF2000 wireless system, locate the receiver module (on the left side of the unit) and disconnect its
4.Take one of the XPFM modules (see Figure 1), set the UNIT dial to channel 2 and the HOUSE dial to the appropriate code (A is usually chosen for first time
5.Take the other module, set the UNIT dial to channel 1 and the HOUSE dial to the same as the other module. Onto a clean mounting surface, place this module on the RIGHT side of the PG2000 with the double stick tape provided. Connect the BLUE wire, the BLACK wire (from the LEFT side XPFM), and the smaller BLACK wire from the Ballast fuse together. Now, connect the RIGHT side XPFM’s BLACK wire to the main’s BLACK wire.
Model
Fixture Module
O . | A . C | 15 . 1 | . | 3 | ||
. | . | . |
|
| . | |
M. |
| .E | 13. |
|
| .5 |
K . |
| . G | 11 . |
| . | 7 |
| I | 9 |
|
HOUSEUNIT
Figure 1.
6.Connect all the WHITE (neutral) wires together with one wire nut (should be 4 white wires in all).
7.Connect the mains GREEN (chassis) wire and the PG2000’s GREEN wire together with a wire nut.
8.Check that all connections are tight and no bare conductors are exposed. Verify connections with the wiring diagram in Figure 4.
9.Replace the PG2000 cover and fasten with screws.
10.Change the side switches to match the Remote Switch Control setting (see Figure 3). Each switch is set to its own remote switch position (power and colorwheel).