Hearth and Home Technologies RCT-MLT-II Installation Instructions, Remote Receiver

Page 2

INSTALLATION INSTRUCTIONS

Installing Electrical Service to the Junction Box

WARNING: TURN ELECTRICAL POWER OFF AT THE CIRCUIT BREAKER BEFORE BEGINNING THIS INSTALLATION.

NOTE: Some appliances do not have a cover plate. Instead, there is a hole through which the Romex clamp is attached to the outer wrap.

1.Remove the electrical cover plate from the lower side of the fireplace. Remove the knock-out from the plate and attach the Romex clamp (screws to the outside) (see Figure 1).

ACCESS HOLE

110 VAC

SERVICE

COVER

PLATE

Figure 1

2.Feed the electrical service wires through the Romex clamp and secure the wires to the clamp.

3.Using the wire nuts provided, connect the service wires to the junction box. The black wires to the black service wire, the white wires to the white service wire, and the service ground wire to the ground stud of the junction box.

4.Re-attach the cover plate to the outside of the fire- place.

WARNING: LEAVE ELECTRICAL POWER OFF AT THIS TIME. DO NOT RESTORE POWER UN- TIL THE REMOTE CONTROL SYSTEM IS COM- PLETELY INSTALLED.

REMOTE RECEIVER

Important: The remote receiver should be positioned close to front in right or left corner where ambient temperatures do not exceed 170º F.

The remote receiver is powered by 110-120VAC. It plugs into a standard polarized duplex receptacle.

Locating Receiver and Operating Functions

This remote receiver can be positioned under the firebox in the control compartment of the fireplace if ambient temperatures do not exceed 170º F. This system is de- signed to control the following components:

 

 

Wire Colors

Gas Valve - Millivolt or

 

 

Electronic Ignition

Red

• Fan/Blower - 110 VAC

Plug from Fan

Flame Controller - HI/LO solenoid

Orange

RECEIVER WIRING INSTRUCTIONS

Incorrect wiring connections WILL cause damage to the gas valve or electronic module operating the gas appli- ance and may also damage the remote receiver.

Wiring Flame Function (Standing Pilot, DSI, IPI)

Connect the remote receiver by connecting the two red wires leading from the remote receiver to the red and brown remote wires labeled “FOR USE WITH REMOTE OR WALL SWITCH ONLY”. See Figure 2.

 

 

 

REMOTE

 

 

 

 

RECEIVER

 

 

 

RED

 

VALVE

 

 

 

TH

ON/OFF

 

 

 

SWITCH

REMOTE SWITCH

 

RED

 

 

 

PIGTAIL

 

TP

 

 

 

 

RED

 

 

TP TH

 

 

 

 

 

BROWN

 

 

 

Figure 2.

WALL

 

 

 

SWITCH

 

 

 

Alternative Wiring for units with a wall switch

Disconnect the wall switch wire from the TH terminal on the valve and connect this wire to male connector sup- plied on the receiver. Connect remaining female connec- tor from receiver to the TH terminal on the valve.

Adding Optional Fan/Blower

Plug 2-prong fan cord directly into the 3 prong polarized plug on the back of the receiver (see Figure 3). This receptacle output is 110/120 VAC, 3 AMP.

(Receptacle on back)

LEARN110/120 VAC, 3A

REMOTE

 

 

 

 

RECEIVER

Line cord

 

from fan

Figure 3. Adding Fan/Blower

2

Image 2
Contents Canadian Equipment Requirements Installation PrecautionsIntroduction Remote Receiver Installation InstructionsReceiver Wiring Instructions Installing Flame Control Solenoid Transmitter Remote ReceiverMatching Security Codes Transmitter SettingsSetting the Clock Operating InstructionsSetting the Countdown Timer Setting ºF/ºC ScaleSetting Desired Room Temperature Thermo Operations Operating the Fan Operates in on or Thermo modeTransmitter Safety Features System CheckGeneral Information Intermittent Pilot Ignition IPI Wiring Diagram Can be Remote Control Wiring Diagrams