Mitsubishi Electronics VS-60609 High Voltage Circuit Purpose, High Voltage Control Symptom

Page 29

MODELS: VS-45609 / VS-50609 / VS-55609 / VS-60609 / VS-60719 / VS-70709

[High Voltage Circuit]

Purpose:

To set the CRTs anode voltages

3. High Voltage Control

Symptom:

Dark picture.

 

 

 

 

 

 

 

Measuring

DC Voltmeter

1.

Supply a Monoscope signal to a Video Input.

Instrument

 

 

Test Point

+ Lead to DT #5

2.

Connect a DC Voltmeter to pins 4 and 5 of the DT connector.

- Lead to DT #4

 

• Positive Lead to DT #5

 

 

 

Ext. Trigger

------

 

 

• Negative Lead to DT #4

 

 

 

 

3.

Set Contrast to maximum, and Brightness to the center position.

Measuring

-------

 

 

4.

Enter the Service Mode and check that Item “7 BRTH” under the VCJ Function is

Range

 

 

 

 

set at 31.

 

Input Signal

Monoscope

 

 

5.

Press Enter and Exit the Service Mode.

 

 

 

 

 

 

Input Terminal

Video Input

6.

Enter the Convergence Mode and select the Conv. Misc Function.

7.

Select Item “1 HVOL” (screen goes black).

 

 

 

 

 

 

 

 

8.

Adjust “1 HVOL” for 0.15 ±0.01 V on the meter.

 

 

 

 

9.

Exit the Convergence Mode and verify that the meter reading does not exceed

 

 

 

 

 

0.85V.

 

 

 

 

 

 

 

Note: HV must be reset if E2RESET is activated.

 

 

CONVERGENCE MODE

 

 

Activate ……..MENU-0-1-5-9

SERVICE MODE

 

Misc. ……………….……"6"

Activate …….. MENU-0-1-5-7

 

 

Coarse………………..…."5"

Function …...………..AUDIO

 

 

Fine ……………………..."4"

Item No. ……….…….VIDEO

 

 

Color (R,G B or DF)...AUDIO

Adjust Data ….…….ADJUST

 

 

Item No………….…..VIDEO

Save Data …. ………ENTER

 

 

Adjust/Move……….ADJUST

Exit …………..MENU (twice)

 

 

Cursor Toggle….…..ENTER

 

 

 

 

Save & Exit…..MENU (twice)

[Focus]

 

Purpose:

To improve edge focus

 

 

4. Dynamic Focus

Symptom:

Blurred picture at the edges of the screen.

 

 

 

 

 

 

 

 

 

Measuring

------

1. Supply a Monoscope signal to the Video Input.

Instrument

 

Test Point

--------

2. Enter the Coarse Convergence Mode and select the DF Function.

3. Verify that the data values are set as indicated in the table below.

 

 

 

Ext. Trigger

------

4. Exit the Convergence Mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring

-------

 

 

 

 

 

 

 

Range

 

 

 

 

 

 

 

 

Input Signal

Monoscope

 

 

 

 

 

CONVERGENCE MODE

 

 

 

 

DF Function

 

 

Activate ……..MENU-0-1-5-9

 

Input Terminal

Video Input

 

 

 

Item

Abbrev.

Data

 

Misc. ……………….……"6"

 

 

 

 

 

 

 

 

 

0

DFH

200

 

Coarse………………..…."5"

 

 

 

 

1

DFV

100

 

Fine ……………………..."4"

 

 

 

 

 

 

 

 

Color (R,G B or DF)...AUDIO

 

 

 

 

 

 

 

 

Item No………….…..VIDEO

 

 

 

 

 

 

 

 

Adjust/Move……….ADJUST

 

 

 

 

 

 

 

 

Cursor Toggle….…..ENTER

 

 

 

 

 

 

 

 

Save & Exit…..MENU (twice)

 

 

 

 

 

 

 

 

 

 

Page 29

Image 29
Contents Mitsubishi Digital Electronics AMERICA, INC VZ9Models Page Contents Service Parts List Circuitry Block Diagrams Chip Parts Replacement Replacement PartsIntroduction Product Safety NoticeLeakage current check Safety PrecautionsRadiation warning Refer to Parts List for Part Numbers Cabinet Disassembly Front ViewFront Cabinet Disassembly Rear Cabinet Disassembly Cabinet Disassembly Rear ViewPage Table a Size Length1c. VS-70709 Cabinet Separation Precedure Cabinet Separation Procedure VS-70709DiamondShield Installation Procedure DiamondShield Removal ProcedureServicing the Diamondshield Top & Bottom Molding Clips Side Molding ClipsMajor Parts Locations Chassis Removal and PCB LocationsRemoval of the CRT CRT ReplacementPage Adjustment procedures after replacing the CRTs Test Signal Electrical AdjustmentsMonoscope Signal Color Bar SignalOption Menu Setup Initial SettingsDefault Settings Description Initial SettingError Code Operational Check LED Indicator DiagnosticsError Codes AV MemoryActivating the Circuit Adjustment Mode Adjustment FunctionsSelection of adjustment Functions Adjustment Items Changing DataConvergence Adjustment Mode Sub Functions Fine Conv PressCursor Cursor CoordinatesDisplay Saving Data and Exiting the Convergence ModePIP Function Adjustment Items ListAudio Function HR Function Convergence Mode ItemsConv Misc Conv GreenConv Blue Conv REDDF Function VkeyPage Audio Circuit Purpose Service ModeInput Level Audio Function Abbrev DataDynamic Focus Symptom High Voltage Control SymptomConvergence Mode High Voltage Circuit PurposeFocus Verification Lens Focus Symptom Blurred pictureMENU-0-1-5-9 Color PressAbbr Data Service Mode CRT Cutoff SymptomCRT Circuit Purpose CRT CurrentService Mode Activate …….. MENU-0-1-5-7 Low Color TemperaturePIP Insert Picture Color and Tint SymptomPIP Circuit Purpose On-screen display is not positioned correctly 13. Cb, Cr Offset SymptomCb, Cr Circuit Purpose Abbr Data Convergence Circuit Purpose Height and Vert. Linearity SymptomDeflection Circuit Purpose Convergence Circuit Purpose Coarse Convergence Color edging at the top, bottom and sides of the picture Fine Convergence SymptomChip Parts Removal Transistors ReplacementChip Parts Removal Resistors, Capacitors, etc Parts Ordering Critical and Warranty Parts DesignationParts Tolerance Codes Model AbbreviationsQuick Reference for Common Replacement Parts Remote ControlCRT Assemblies High Voltage / Deflection ComponentsIntegrated Circuits TubesTransistors DiodesCOIL-CHOKE ZTS6620 CoilsResistors TransformersVariable Resistors Carbon 1/4W 10K-J R521R529 Fuse 1/2W 0.82-JComposition 1/2W 1M-K Capacitors & TrimmersComposition 1/2W 4.7M-K CER-CHIP SL50V 470P-J CER-CHIP CH50V 82P-JCER-CHIP CH50V 47P-J CER-CHIP CH50V 68P-JC554 C552PLA-PP 200V 0.47M-J C568Poly 250VAC 0.1M-M C902 C901Poly 250VAC 0.1M-M C903 CER 250VAC 1000P-M C904Printed Circuit Boards AccessoriesMiscellaneous Screen Parts Screen Assembly Circuitry Block Diagrams Power SupplyVIDEO/COLOR Signal Path Sound Circuit Deflection Protect Circuit Convergence Circuitry Control Circuit Page Page Page Page Page Page Page Page Page Page Page