AVE AVE DR16X, MV DR8X, AVE DR8X, MV DR16X user manual 3 RS485 Setup

Page 41

User’s Manual

To configure dome protocol, select a camera first and set the communications protocol associated with dome camera using the Direction keys and ENTER. The available protocol includes <DynaColor>, <Pelco D>, <Pelco P>, <AD422>, <Fastrax 2> and <None> (default).

NOTE: The settings become effective after saving the changes and exiting from the menu.

4.6.3RS485 Setup

AVE DR16X / AVE DR8X series controls the domes via RS-485 communication protocol. The RS-485 parameters of AVE DR16X / AVE DR8X series must be set to the same as the parameters set in dome camera .

Users are allowed to change the RS-485 settings of the AVE DR16X / AVE DR8X series. Select <System Setup> in Main menu, then select <RS485 Setup> from the System Setup menu and press ENTER. The following menu is displayed.

 

 

RS485 Setup

1

Unit ID

224

2

Baud Rate

9600

3

Bits

8

4

Stop

1

5

Parity

None

The ID number must match the ID address set by the dome. The Unit ID is in the range of 1 to 255. The default ID is 224. Note that no two devices on the same bus should be given the same ID address, or a conflict may occur.

The default AVE DR16X / AVE DR8X series RS-485 settings are 9600 Baud, 8 Data Bits, 1 Stop Bit and No Parity.

NOTE: The settings become effective after saving the changes and exiting from the menu.

40

Image 41
Contents Ver User’s Manual User’s Manual Rack Mounting Important InformationTable of Content Sequence with Main Monitor Sequence with Call Monitor Overview Product Key FeaturesUser’s Manual System Setup Product Application DiagramConnecting Required Devices Connecting Devices to the UnitPosition the Unit Selecting Video FormatRear Panel Connections Connecting Short-term DeviceMain Monitor S-Video / BNC Call Monitor BNCPower Jack LAN Connector RJ-45Power Switch Camera LoopingUSB Connector Alarm I/O & RS485VGA Out RS-232CLED Definition General System SetupFront Panel Introduction Functional Keys Fast Forward Fast RewindCall/ Copy Instant RecordSEQ Sequence Direction Keys Install HDD to the UnitTo Power Up the Unit Power Up / Down the UnitPower Off RebootAdministrator Password User Password Entering OSD Setup MenuSet Date / Time System Date / Time SettingSet Date / Time Date / Time DisplayDaylight Saving Time DST Bias Record Schedule / Quality SettingRecord Mode Normal PPS Normal Size Event PPS Event Size Schedule SetupPreset Record Configuration To Record Event Video Only Per Camera ConfigurationViewing Live / Playback Video Basic OperationViewing Modes Viewing in Full ScreenViewing Live Cameras Digital ZoomTo Freeze Live Image Viewing Recorded VideoPause Playback and Single Step Forward Key Usage in PlaybackDual Main Output For Unit with Turbo Module Viewing Live Image in Playback ModeSequence with Call Monitor Sequence SetupSequence with Main Monitor Searching Recorded Video Searching by Event Searching by TimeVideo Export Export from OSD Setup MenuDevice Name Select the External DeviceAvailable SelectSelect Channel Select Video for ExportingFrom / To Time Select EventsErase Disc Digital SignatureQuick Video Export through Front Panel Export FormatTo Export Normal Video EzBurn IntroductionTo Export Event Video Dome Control Deleting Recorded VideoPurge All Data Purge All Event DataDome Connection Dome Protocol Setup3 RS485 Setup Dome Controlling Key Pan / Tilt Setting Preset PointsZoom Out Calling Preset Points All specifications are subject to change without notice Appendix a Technical SpecificationsUser’s Manual