Paragon PC-620-2, PC-620-1 manual Optimizing Your Cleaner Tanks, Temperature

Page 13

Optimizing Your Cleaner

Tanks

Cleaning - check the tank for contamination whenever you change solution. If necessary, remove contaminants with a nonabrasive cloth and water.

Emptying - always unplug the cleaner before emptying the tank. Dispose of the contents in an environmentally responsible way.

Filling - always unplug the line cord before filling the tank. Fill the cleaner to the operating level (one inch from the top with beaker/tray in place), using warm tap water.

Low solution level - will cause the cleaner to fail. When you remove heavy or bulky loads from the cleaner, the solution level may drop below the operating level. If so, be sure to replace lost solution and degas, if necessary, depending on the amount used.

Overload - do not rest any items on the tank bottom. Weight on the tank bottom dampens sound energy and will cause damage to the transducer. Instead, use a basket or other method to support all items. Allow at least one inch between the tank bottom and the parts or receptacle for adequate cavitation.

Covers - allow the cleaner to heat up faster, to a higher temperature, and avoid excessive liquid evaporation. However, leaving the cover on with heat and ultrasonics can cause the solution to boil, diminishing effectiveness.

Temperature

Heater - the heater may cause some discoloration of the tank wall. This is normal and will not affect the performance of the unit.

Solution - the fastest method to get your cleaner to the best operating temperature is to fill it with warm solution, turn on both the heat and ultrasonics, and use a cover.

9Operating Your Cleaner

Image 13
Contents Operator’s Manual Warranty Contents Page To avoid electrical shock Safety PrecautionsTo prevent personal and/or property damage To prevent damage to the cleaner PC620 General Information IntroductionUnpacking Your Cleaner Accessories For Your CleanerInstalling Your Cleaner Model Tank Overall Weight Heater Input Volume Size Power Equipment SpecificationsHow Ultrasonic Cleaning Works Before You Start Cleaning Operating Your CleanerGetting Ready Cleaning ItemsTemperature Optimizing Your Cleaner TanksApplication Hints Alkaline strength Removes Cleaning Solutions Solution TypesChemicals Harmful to Your Tank Chemistry ConcentrationsTroubleshooting Glass Slide Test PerformanceAuthorized Service Centers ServiceCPN-214-159