Philips DVR1EP16, DVR1EP08 Appendix E RS-232 Remote Protocol, Supported Command Sequences

Page 38

APPENDIX E: RS-232 REMOTE PROTOCOL

1.1Supported Command Sequences

The DVR1 supports the following command sequences, entered via PC once communication has been established between the PC and the DVR1. The Baud Rate should be set at 9600 Baud, with 1 Stop Bit, 8 Data Bits, and Parity at None.

All byte values entered at the PC must be in hexadecimal values. Each command string begins with an STX (02) character and ends with an ETX (03) character.

 

 

START

 

 

 

END

COMMAND

CHARACTERS

1

2

3

4

5

Play Forward

FPL

02

46

50

4C

03

Record

REC

02

52

45

43

03

Stop

STO

02

53

54

4F

03

Pause

PAU

02

50

41

55

03

Fast Forward

FWD

02

46

57

44

03

Rewind

REW

02

52

45

57

03

Frame Advance

FAD

02

46

41

44

03

Reverse Frame

 

 

 

 

 

 

Advance

RAD

02

52

41

44

03

Play Reverse

RPL

02

52

50

4C

03

Set Clock

 

See instructions for setting clock in the following section.

 

Increase Speed

ISP

02

49

53

50

03

Decrease Speed

DSP

02

44

53

50

03

Search

SEA

02

53

45

41

03

Arrow Up

ARU

02

41

52

55

03

Arrow Down

ARD

02

41

52

44

03

Arrow Left

ARL

02

41

52

4C

03

Arrow Right

ARR

02

41

52

52

03

Menu

MEN

02

4D

45

4E

03

Enter

ENT

02

45

4E

54

03

 

 

 

 

 

 

 

Example:

To Play Forward, enter the following command at the PC keyboard, using the starting and ending characters and hexadecimal equivalent of the FPL from the above chart: 02 46 50 4C 03 <Enter>

1.2Setting the Clock

The following table shows the command sequence for setting the clock.

COMMAND

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VALUE

02

43

4C

4B

20

y1

y2

2D

m1

m2

2D

d1

d2

2C

h1

h2

3A

f1

f2

03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The gray cells in the Value row of the table indicate the correct positions for each byte of data in the command string.

Place the hexadecimal value of the desired ASCII character into the command string, entering two digit values for Year, Month, Day, Hour, and Minute into the command string. The year is a 2-digit number, and the time is military time (24-hour clock).

See the example to follow.

38

Image 38
Contents DVR1 Series Single Channel, Color Digital Video Recorder Philips Communication Security & ImagingImportant Safeguards FCC & Ices InformationSafety Precautions Securite Sicherheitsvorkehrungen Precauciones DE Seguridad Veiligheidsmaatregelensicurezza Medidas DE Segurança Zasady Bezpieczeństwa Table of Contents Service and Returns Unpacking Introduction to DVR1 Series Digital Video RecordersGuide to This Manual Understanding the DVR1 SeriesMounting Installing the DVR1Connecting the DVR1 DB-9 Connector on High 12 DVR1 Front Panel Display Guide to the DVR1 ControlsDVR1 Front Panel Controls Navigating with the DVR1 Controls Main Menu Record Settings Normal Record SpeedDate Format Setup Select Format Not highlightedDVR1 Main Menu Programming Setting the Time/DateConfiguring Alarms Overview of the DVR1 Main MenuConfiguring the Recording Parameters Configuring Scheduled RecordingsMain Menu Timer Settings Main Menu Record SettingsMain Menu Archive Setup Configuring On-screen Display OptionsMain Menu Display Settings Main Menu Archive Setup Selective ArchiveMain Menu Archive Setup Archive Overwrite Mode Main Menu Archive Setup Restore From ArchiveMain Menu Archive Setup Background Archive About DSR Main Menu Archive Setup Erase Archive MediumAccessing the Advanced Menu Main Menu About DSRDVR1 Advanced Menu Programming DVR1 PasswordsPassword BOX Please Enter the Password Overview of the DVR1 Advanced MenuOverwriting the Hard Disk Erasing, Deleting, and Recovering Hard Disk DataUsing the Auto Delete Feature Invoking Audio RecordingAdjusting Picture Qualities Configuring CommunicationsConfiguring the Multiplexer Format Locking Out the Front PanelChanging the Password Restoring Factory DefaultsAdvanced Menu Factory Settings Advanced Menu Change PasswordRecording Operating the DVR1 SeriesInitial Startup Playback Message Disk FULL. Recording has StoppedSearch Interface Archiving Applications Explained Using CD-WritersArchiving Minimum Write Speed Minimum Read Speed Interface SCSI-2Creating a CD-ROM with Video Files Limitations on CD OperationsFactory Service Service and ReturnsMaintenance All of our products now come with a 3 year warrantyAppendix a Factory Default Settings Function SettingConnections Appendix B Technical SpecificationsGeneral AUDIO/VIDEOON-SCREEN Video Indicators Part NumbersIntroduction Required Software Version Appendix C REO Quick Install GuideInstallation Select Menu Advanced MENU, then press Enter Programming the REO System monitorProgramming the DVR1 Remote Viewing ConsiderationsOverview Multiplexer DVR1DVR1 Keyboard Menus DVR1 Controls2 DVR1 Playback Controls Menu Command Characters Supported Command SequencesSetting the Clock Appendix E RS-232 Remote ProtocolSET Clock Example 3935 890 36813 Bosch Security Systems, Inc