Philips FPF42C128135UA-52 Service Modes, Error Codes, and Fault Finding, Repair Tools

Page 10

EN 10

 

5.

 

FHP PDP

Service Modes, Error Codes, and Fault Finding

5. Service Modes, Error Codes, and Fault Finding

Index of this chapter:

5.1Repair Tools

5.3Process Flow

5.4Repair Instructions

5.5Defect Description Form

5.1Repair Tools

To be able to repair the Plasma Display Panels on board level, the following repair tools are available:

Special LVDS cable: T.B.D.

Foam buffers: 3122 785 90581.

E_14580_024.eps 250304

Power Supply

CN06

Logic Board

CN01

CN06

3 Vpr

CN01

14

3k3

SDA

 

8

 

6

GND

 

 

4

SCL

 

 

I2C

3k3

 

Compair

I2C

Compair

 

G_16400_018.eps 270706

Figure 5-2 Foam buffers for FTV

5.2Error codes

When an error causes the PDP to switch “OFF”, an error code is put into an EEPROM on the Logic Board. You can read out the contents of the error code memory with the ComPair tool.

5.2.1 How to Connect the ComPair Tool

• Carefully disconnect the LVDS cable from CN01 on the

Logic Board.

Figure 5-1 Extension cable kit ALiS PDP

• If necessary connect a PSU with a voltage of 3.3V to drive

the LOGIC board.

• Connect the cable from the ComPair tool to connector

CN01 of the LOGIC board.

• Turn on the ComPair tool.

• Launch the ComPair software.

• Read out the error buffer.

5.2.2Error Code Overview

Table 5-1 Error code table

Error code

Detected by board

Error description

Suspected board(s)

 

 

21

X-SUS

Vxx power voltage is too high

X-SUS

LOGIC

 

 

 

 

 

 

 

 

 

24

 

Vxx power voltage is too low

X-SUS

LOGIC

 

 

 

 

 

 

 

 

 

25

 

Vex power voltage is too high

X-SUS

 

 

 

 

 

 

 

 

 

 

26

 

Vex power startup is faulty

X-SUS

LOGIC

 

 

 

 

 

 

 

 

 

44

Y-SUS

Vey power voltage is too low

Y-SUS

LOGIC

 

 

 

 

 

 

 

 

 

45

 

Vey power voltage is too high

Y-SUS

 

 

 

 

 

 

 

 

 

 

46

 

Vey power startup is faulty

Y-SUS

LOGIC

 

 

 

 

 

 

 

 

 

4C

 

Temperature too high

Y-SUS

LOGIC

 

 

 

 

 

 

 

 

 

61

X-SUS

Vs power voltage is too high

Y-SUS

X-SUS

LOGIC

PSU

 

Y-SUS

 

 

 

 

 

62

Vs power startup is faulty

X-SUS

Y-SUS

PSU

LOGIC

 

 

 

 

 

 

 

64

 

Ve power voltage is too low

LOGIC

X-SUS

Y-SUS

 

 

 

 

 

 

 

 

65

 

Ve power voltage is too high

Y-SUS

Y-SUS

 

 

 

 

 

 

 

 

 

66

 

Ve power startup is faulty

LOGIC

X-SUS

Y-SUS

 

 

 

 

 

 

 

 

68

 

Vw power voltage is too low

Y-SUS

LOGIC

 

 

 

 

 

 

 

 

 

69

 

Vw power voltage is too high

LOGIC

Y-SUS

 

 

 

 

 

 

 

 

 

6A

 

Vw power startup is faulty

Y-SUS

LOGIC

 

 

 

 

 

 

 

 

 

79

 

Vw power current is too high (during operation)

Y-SUS

X-SUS

LOGIC

 

 

 

 

 

 

 

 

7B

 

Vs power voltage is too high (during startup)

Y-SUS

X-SUS

LOGIC

 

 

 

 

 

 

 

 

Image 10
Contents Contents Colour Television ModuleSerial Numbers Technical SpecificationsSpecifications Index of this chapterConnector positions PWB locationsSome connector layouts Lvds connector CN1 Logic BoardSafety Instructions, Warnings, and Notes Safety InstructionsBoard Swap Instructions Directions for UseMechanical Instructions GeneralSUS Circuit Board Radiation plate positionMechanical Instructions ABUS-L Circuit Board ABUS-R Circuit BoardLogic Board PSU BoardHow to Connect the ComPair Tool Service Modes, Error Codes, and Fault FindingError codes Repair ToolsAdvanced PDP Exchange Actual Way-of-Working Process FlowCustomized Repair 2 42 A4 ALiS Plasma Display Panel Repair InstructionsRemark Fault Finding Flowcharts Problem analysis procedure PDP repair / board swapProblem Analysis Procedure The entire screen does not light Short-circuit check on Boards and Power Supply Lines ABUS-L board CN52 pins 1 3 or CN52 pins 4 Are shorted? Procedure Case of Logic Board replacementFollow the Logic Board Exchange Vertical line/Vertical bar problem analysis procedure Replace the defective parts G16400032.eps Horizontal bar problem analysis procedure Logic Board Exchange Logic Board Exchange Fault Fault status Contents #$% Philips Block Diagrams, Test point Overview, and Wave Forms Block DiagramsPower block diagram Test Points Wave FormsVoltage Setting Procedure Circuit Diagrams and PWB LayoutsAlignments Circuit Descriptions and Abbreviation List Board Function DescriptionDifferences between the Versions A1, A2, A3, and A4 Specifications 42A1 42A2 42A3 42A4Layouts SUS Spare Parts List List of abbreviationsRevision List Overview of chassis and manuals, covered by This manual

FPF42C128135UA-52 specifications

The Philips FPF42C128135UA-52 is a state-of-the-art lighting solution designed to meet the needs of modern residential and commercial spaces. This fixture exemplifies innovation, efficiency, and aesthetic appeal, making it a popular choice among architects and interior designers.

One of the main features of the FPF42C128135UA-52 is its energy efficiency. Utilizing advanced LED technology, this fixture consumes significantly less energy compared to traditional incandescent or fluorescent lighting. It boasts a remarkable efficacy that ensures maximum illumination with minimal power consumption, resulting in lower energy bills and a reduced carbon footprint.

The design of the FPF42C128135UA-52 is another defining characteristic. Philips has mastered the balance between functionality and aesthetics, creating a product that seamlessly integrates into a variety of environments. Its sleek, contemporary design makes it suitable for both residential applications, such as living rooms and kitchens, as well as commercial settings, like offices and retail spaces. The fixture is available in multiple color temperatures, allowing users to choose between a warm, inviting light or a bright, energetic glow, depending on the desired ambiance.

In addition to its aesthetic and efficiency qualities, the FPF42C128135UA-52 incorporates smart lighting technologies. Many models in this range are compatible with various smart home systems, enabling users to control their lighting remotely through smartphones or voice-activated devices. This level of customization provides added convenience, allowing users to adjust brightness levels and create dynamic lighting scenes that enhance their living and working environments.

Durability is yet another advantage of the FPF42C128135UA-52. Built with high-quality materials, this fixture promises longevity and reliability over time. Its robust construction ensures it can withstand the rigors of daily use while maintaining peak performance, making it an excellent investment for both homeowners and business owners.

In summary, the Philips FPF42C128135UA-52 is a versatile and efficient lighting solution that combines cutting-edge technology with stylish design. With its energy-saving capabilities, smart compatibility, and durable construction, it stands out as an exemplary choice for anyone looking to enhance their space’s lighting while embracing sustainability and innovation. Whether for home or business, this Philips fixture is bound to illuminate with class and efficiency.