EN 14 |
| 5. |
| FHP PDP | Service Modes, Error Codes, and Fault Finding |
Problem Analysis Procedure: The entire screen does not light
1
The entire screen does not light
Remove CN06
(on LOGIC Board,
All the boards are connected
Connect the set to mains.
Switch “ON” the set via the mains switch
Vpr2 (3.3 V) on | N |
the PSU board is present? |
|
Y
Turn “OFF” AC power
Connect CN 6 (LOGIC)
Turn on AC power
Vpr2 (3.3 V) on | N |
the PSU board is present? |
|
Y
Disconnect the mains plug.
Remove the following power connections:
on
on
on
2
Caution 1: never disconnect connectors or remove boards when the mains plug is connected. Allow discharge of power supplies before disconnecting connectors!
Caution 2: do not interchange boards between different PDPs, this might damage your PDP
PSU board is defective
Replace the
Power Supply
LOGIC board is
defective
Replace Logic Board
Follow the
“Logic Board Exchange” procedure
G_16400_026.eps 310706