INSTALLATION

Installation site

To operate this unit properly and to obtain maximum performance, install the unit in a location with the following conditions:

1. A location not subjected to direct sunlight or direct air flow from an air conditioner

2.A location with adequate ventilation

Leave at least 30 cm around the unit for ventilation. Poor ventilation will result in a reduction of the performance.

3.A location away from heat generating sources

Avoid installing the unit near heat-emitting appliances such as gas ranges or stoves.

4.A location with a sturdy and level floor

WARNING

Install the unit on a sturdy floor. If the floor is not strong enough or the installation site is not adequate, this may result in injury from the unit falling or tipping over.

Select a level and sturdy floor for installation. This precaution will prevent the unit from tipping. Improper installation may result in water spillage or injury from the unit tipping over.

5.A location without flammable or corrosive gas

WARNING

Never install the unit in a flammable or volatile location. This may cause explosion or fire.

Never install the unit where acid or corrosive gases are present as current leakage or electric shock

may result due to corrosion.

6.A location not prone to high humidity

WARNING

Do not use the unit outdoors. Current leakage or electric shock may result if the unit is exposed to rain

water.

Never install the unit in a humid place or a place where it is likely to be splashed by water.

Deterioration of the insulation may result which could cause current leakage or electric shock.

10

Image 11
Contents MOV-112S MOV-212S Contents Precautions for Safe Operation Precautions for Safe Operation \WARNING Precautions for Safe Operation Environmental Conditions Sterilizer Components Sterilizer Components Control panel and keypad Location with a sturdy and level floor InstallationInstallation site Location away from heat generating sourcesPrerunning InstallationBefore Commencing Operation Operating Instructions Basic operating flow chart of control panelSterilization Timer functionStable running Press the power key Stable running with delay timeStart of operation with no change of setting Chamber temperature 50C, Delay time 1 hourSterilization with timer mode Alarms & Safety Functions Cleaning the frame Routine MaintenanceCleaning of unit Cleaning the insideDisposal of Unit Trouble ShootingKey operation is disabled If the alarm function operatesPerformance SpecificationsSafety check sheet