Technical Guide
August 2007
DANIEL® SERIES 1200 LIQUID TURBINE FLOW METER
Daniel Series 1200 Liquid Turbine Flow Meters are designed specifically for load rack service where a vital characteristic is repeatability. The meter deploys a lightweight rotor which is supported on
The meter features an upstream expanding hanger which centers the internals in the body, with cantilevered support of the rotor. The stainless steel ball bearings or the tungsten carbide bearings and the shaft are housed in the meter hub. The meter will operate in any plane, and is frequently used in the vertical orientation with flow upward to save space at a load rack.
The design includes an integral flow conditioning plate which allows operation without upstream flow straightening available on the 1.5”, 2”, 3” and 4” meters. This configuration is particularly valuable in vertical use at load racks.
SEE DANIEL SERIES 1200 LIQUID TURBINE FLOW METER DATASHEET FOR MODEL SELECTION MATRIX
UMB Cover
Dual Channel
Figure 9 - Daniel® Series 1200Pre-amplifer
Liquid Turbine Flow Meter
(Shown with tungsten carbide bearings)
Pickoffs
UMB Housing
Outlet
Diffuser
Cap
Hanger Shaft
Sleeve
Flow Conditioning Plate
Blades
Rotor
Thrust Assembly
Washer with
Bearing
Hanger
Hub
Page