Emerson TG-0807 manual Turbine Meter Parameters, Flow Ranges +0.15% +0.02%

Page 4

Technical Guide

DAN-LIQ-Turbine Meter-TG-0807

August 2007

TURBINE METER PARAMETERS

These five terms are the most widely discussed parameters of turbine meter applications.

Linearity is the measure of variation in signal output across the nominal flow range of the meter. The turbine meter will have a nominal K-factor (number of pulses output for a given volume measured) and this value varies across the flow range of the meter. Linearity is a measure of the variance of actual output from the average K-factor. With modern electronics, linearization of the meter registration is possible within a flow computer, and thus further improvements in measurement accuracy is possible.

Repeatability is the ability of a meter to indicate the same reading each time the same flow conditions exist. Turbine meters exhibit excellent repeatability and, for many control applications, this is the most important parameter to be considered.

Accuracy is a measure of how close to true or actual flow the instrument indication may be. It is generally expressed as a percent of true volume for a specific flow range. This is a “worst case” rating. Accuracy at a particular flow rate may be an order of magnitude better than “rated flow range accuracy.”

Resolution is a measure of the smallest increment of total flow that can be individually recognized, normally defined by a single pulse. Turbine meters have an inherently high resolution.

Range is the ratio of maximum flow to minimum flow over which the specified linearity will be maintained. Normal range (or “turn-down”) is given as 10:1, although this may be exceeded in many cases, depending on meter size and required linearity.

Figure 1 - Flow Ranges

+0.15%

–0.15%

+0.02%

–0.02%

Page

Image 4
Contents Daniel Liquid Turbine Flow Meter Technical Guide Page Table of Contents ForewordTurbine Meter Parameters Flow Ranges +0.15% +0.02%Liquid Turbine Flow Meter System Flow Computer Daniel Valves In Load Rack Duty Turbine Meter TheoryPatented* Floating Rotor Surge And Pressure Relief Valves Magnetic Pickoff of Rotor VelocityTurbine Meter Rotor and Bearing Design Rimmed Rotors for Higher Resolution Daniel Series 1200 Liquid Turbine Flow Meter Daniel Series 1200Pre-amplifer Liquid Turbine Flow MeterSize Inches Standard Linearity Premium Linearity Size Standard Extended InchesSize Factor Inches Pulses/BBL Pulses/M Pulses/US Gal Standard Optional Daniel Series 1500 Liquid Turbine Flow Meter Daniel Series Liquid Turbine Flow MeterExtended Extended Max Standard FlowStandard Flow Range Inches Range BBL/Hr BPH w/20% Range M 3/HrNominal K-Factor Size Pulses/BBL Pulses/M Pulses/US Gal Rangeability of Liquid Turbine Flow Meters = 1 .7 to Meter Size Minimum Linear Maximum Linear BBL/Hr Meter Performance in High Viscosity Liquids Sizing RatioInstallation and Operating Recommendations Small Diameter Meter TubeBack Pressure Effects of Back PressurePickoff Specifications Turbine Meter InstrumentationPage Stirling, Scotland Europe, Middle East, Africa