Technical Guide
August 2007
DANIEL® SERIES 1200 LIQUID TURBINE FLOW METER DESIGN FEATURES
The following data is applicable for Daniel Series 1200 Liquid Turbine Flow Meter calibrated on mineral spirits.
Size | Standard | Extended | Standard | Extended | Standard | Extended | ||
(Inches) | Flow Range | Flow Range | Flow Range | Flow Range | Flow Range | Flow Range | ||
| BBL/Hr | BBL/Hr | M3/Hr | M3/Hr | USGPM | USGPM | ||
1 | 8.6 | - 86 | 99 | 1.36 | - 13.7 | 15.8 | 6.0 - 60 | 69 |
1.5 | 18.6 | - 186 | 214 | 2.96 | - 29.6 | 34 | 13 - 130 | 150 |
2 | 31.5 | - 315 | 362 | 50 | - 50 | 57.5 | 22 - 220 | 253 |
3 | 93 - 930 | 1.071 | 14.8 - 148 | 170 | 65 - 650 | 750 | ||
4 | 143 - 1,430 | 1,785 | 23 - 230 | 284 | 100 - 1,000 | 1,250 |
Linearity
Size (Inches) | Standard Linearity | Premium Linearity |
1 | N/A | |
|
|
|
1.5 | ||
2 | ||
3 | N/A | |
|
|
|
4 | N/A | |
|
|
|
Repeatability:
Nominal K- factor
Size |
|
|
|
|
|
|
|
(Inches) | Pulses/BBL | Pulses/M3 | Pulses/US Gal |
1 | 33,600 | 211,360 | 800 |
1.5 | 16,800 | 105,680 | 400 |
2 | 7,560 | 47,556 | 180 |
3 | 2,184 | 13,877 | 52 |
|
|
|
|
4 | 966 | 6,077 | 23 |
|
|
|
|