DANIEL® SERIES 1200 LIQUID TURBINE FLOW METER DESIGN FEATURES

The following data is applicable for Daniel Series 1200 Liquid Turbine Flow Meter calibrated on mineral spirits.

Size

Standard

Extended

Standard

Extended

Standard

Extended

(Inches)

Flow Range

Flow Range

Flow Range

Flow Range

Flow Range

Flow Range

 

BBL/Hr

BBL/Hr

M3/Hr

M3/Hr

USGPM

USGPM

1

8.6

- 86

99

1.36

- 13.7

15.8

6.0 - 60

69

1.5

18.6

- 186

214

2.96

- 29.6

34

13 - 130

150

2

31.5

- 315

362

50

- 50

57.5

22 - 220

253

3

93 - 930

1.071

14.8 - 148

170

65 - 650

750

4

143 - 1,430

1,785

23 - 230

284

100 - 1,000

1,250

Linearity

Size (Inches)

Standard Linearity

Premium Linearity

1

+/-0.25%

N/A

 

 

 

1.5

+/-0.25%

+/-0.15%

2

+/-0.25%

+/-0.15%

3

+/-0.15%

N/A

 

 

 

4

+/-0.15%

N/A

 

 

 

Repeatability: +/-0.02% at any point throughout the minimum to extended maximum flow range.

Nominal K- factor

Size

 

K-factor

 

 

 

 

 

(Inches)

Pulses/BBL

Pulses/M3

Pulses/US Gal

1

33,600

211,360

800

1.5

16,800

105,680

400

2

7,560

47,556

180

3

2,184

13,877

52

 

 

 

 

4

966

6,077

23

 

 

 

 

Page

Image 12
Contents Daniel Liquid Turbine Flow Meter Technical Guide Page Table of Contents ForewordTurbine Meter Parameters Flow Ranges +0.15% +0.02%Liquid Turbine Flow Meter System Flow Computer Daniel Valves In Load Rack Duty Turbine Meter TheoryPatented* Floating Rotor Surge And Pressure Relief Valves Magnetic Pickoff of Rotor VelocityTurbine Meter Rotor and Bearing Design Rimmed Rotors for Higher Resolution Daniel Series 1200 Liquid Turbine Flow Meter Daniel Series 1200Pre-amplifer Liquid Turbine Flow MeterSize Standard Extended Inches Size Inches Standard Linearity Premium LinearitySize Factor Inches Pulses/BBL Pulses/M Pulses/US Gal Standard Optional Daniel Series 1500 Liquid Turbine Flow Meter Daniel Series Liquid Turbine Flow MeterExtended Extended Max Standard FlowStandard Flow Range Inches Range BBL/Hr BPH w/20% Range M 3/HrNominal K-Factor Size Pulses/BBL Pulses/M Pulses/US Gal Rangeability of Liquid Turbine Flow Meters = 1 .7 to Meter Size Minimum Linear Maximum Linear BBL/Hr Meter Performance in High Viscosity Liquids Sizing RatioInstallation and Operating Recommendations Small Diameter Meter TubeBack Pressure Effects of Back PressurePickoff Specifications Turbine Meter InstrumentationPage Stirling, Scotland Europe, Middle East, Africa