Emerson TG-0807 manual = 1 .7 to Meter Size Minimum Linear Maximum Linear BBL/Hr

Page 18

Technical Guide

DAN-LIQ-Turbine Meter-TG-0807

August 2007

DANIEL® SERIES 1500 LIQUID TURBINE FLOW METER SPECIFIC GRAVITY ADJUSTMENTS

S.G. = 1 ( .7 to 1 )

Meter Size

 

Minimum Linear

 

 

Maximum Linear

 

 

BBL/Hr

 

M3/Hr

 

USGPM

BBL/Hr

 

M3/Hr

 

USGPM

1

10

 

1.59

 

7

100

 

15.90

 

70

1.5

21.4

 

3.40

 

15

214

 

34

 

150

2

35.7

 

5.68

 

25

357

 

56.76

 

250

2.5

57.1

 

9.08

 

40

571

 

90.78

 

400

3*

100

 

15.9

 

70

1,000

 

159

 

700

4*

185.7

 

29.52

 

130

1,850

 

295

 

1,295

6*

420

 

66.77

 

294

4,192

 

667.7

 

2,935

S.G. = 0.5

 

 

 

 

 

 

 

 

 

 

Meter Size

 

Minimum Linear

 

 

Maximum Linear

 

 

BBL/Hr

 

M3/Hr

 

USGPM

BBL/Hr

 

M3/Hr

 

USGPM

1

22.9

 

3.64

 

16

116

 

36.4

 

81

1.5

50

 

7.95

 

35

246

 

79.5

 

172

2

84.3

 

13.40

 

59

411

 

134

 

288

2.5

134.3

 

21.35

 

94

657

 

213.5

 

460

3*

235.7

 

37.47

 

165

1,150

 

374.7

 

805

4*

435.7

 

69.27

 

305

2,127

 

692.7

 

1,489

6*

988.6

 

157.2

 

692

4,830

 

1,572

 

3,381

S.G. = 0.3

 

 

 

 

 

 

 

 

 

 

Meter Size

 

Minimum Linear

 

 

Maximum Linear

 

 

BBL/Hr

 

M3/Hr

 

USGPM

BBL/Hr

 

M3/Hr

 

USGPM

1

32.9

 

5.23

 

23

116

 

52.3

 

81

1.5

71.4

 

11.35

 

50

246

 

113.5

 

172

2

118.6

 

18.56

 

83

411

 

185.6

 

288

2.5

190

 

32.21

 

133

657

 

322.1

 

460

3*

331.4

 

52.69

 

232

1,150

 

526.9

 

805

4*

612.8

 

97.43

 

429

2,127

 

974.3

 

1,489

6*

1,393

 

221.5

 

975

4,830

 

2,215

 

3,381

* Rim type rotor not recommended, use blade type rotor only.

Page 15

Image 18
Contents Daniel Liquid Turbine Flow Meter Technical Guide Page Table of Contents ForewordTurbine Meter Parameters Flow Ranges +0.15% +0.02%Liquid Turbine Flow Meter System Flow Computer Daniel Valves In Load Rack Duty Turbine Meter TheoryPatented* Floating Rotor Surge And Pressure Relief Valves Magnetic Pickoff of Rotor VelocityTurbine Meter Rotor and Bearing Design Rimmed Rotors for Higher Resolution Daniel Series 1200 Liquid Turbine Flow Meter Daniel Series 1200Pre-amplifer Liquid Turbine Flow MeterSize Standard Extended Inches Size Inches Standard Linearity Premium LinearitySize Factor Inches Pulses/BBL Pulses/M Pulses/US Gal Standard Optional Daniel Series 1500 Liquid Turbine Flow Meter Daniel Series Liquid Turbine Flow MeterStandard Flow Range Extended Extended MaxStandard Flow Inches Range BBL/Hr BPH w/20% Range M 3/HrNominal K-Factor Size Pulses/BBL Pulses/M Pulses/US Gal Rangeability of Liquid Turbine Flow Meters = 1 .7 to Meter Size Minimum Linear Maximum Linear BBL/Hr Meter Performance in High Viscosity Liquids Sizing RatioInstallation and Operating Recommendations Small Diameter Meter TubeBack Pressure Effects of Back PressurePickoff Specifications Turbine Meter InstrumentationPage Stirling, Scotland Europe, Middle East, Africa