RIMMED ROTORS FOR HIGHER RESOLUTION

In the larger diameter Daniel Series 1500 Liquid Turbine Flow Meter (normally above 6” in line size), the resolution provided by a blade-type motor may be improved by the use of a rimmed (or shrouded) rotor. This construction is standard for Daniel meters of 8” and up. A lightweight stainless steel rim (or shroud) carries small paramagnetic buttons which provide a greater resolution of flow by generating more pulses per unit volume.

Daniel Series 1200 and 1500 Liquid Turbine Flow Meters are supplied with one Universal Mounting Box (UMB) as standard. This is attached to a boss, which in turn is attached to the meter body. This assembly may house two pickoffs, which are oriented such that their outputs are 90º electrically out of phase.

Figure 7 - Daniel® Series 1500 Liquid Turbine Flow Meter internals showing standard rimmed rotor

Figure 8 - Daniel® Series

1500 Liquid Turbine Flow Meter internals showing high resolution rotor

The Daniel® Series 1500 Liquid Turbine Flow Meter is also offered with a high resolution rotor. This rotor is designed with slots in the rim in place of paramagnetic buttons and provides a higher number of pulses per unit volume than the standard rotor which enables proving with a smaller pipe size prover.

Page

Image 10
Contents Daniel Liquid Turbine Flow Meter Technical Guide Page Table of Contents ForewordTurbine Meter Parameters Flow Ranges +0.15% +0.02%Liquid Turbine Flow Meter System Flow Computer Daniel Valves In Load Rack Duty Turbine Meter TheoryPatented* Floating Rotor Surge And Pressure Relief Valves Magnetic Pickoff of Rotor VelocityTurbine Meter Rotor and Bearing Design Rimmed Rotors for Higher Resolution Daniel Series 1200 Liquid Turbine Flow Meter Daniel Series 1200Pre-amplifer Liquid Turbine Flow MeterSize Inches Standard Linearity Premium Linearity Size Standard Extended InchesSize Factor Inches Pulses/BBL Pulses/M Pulses/US Gal Standard Optional Daniel Series 1500 Liquid Turbine Flow Meter Daniel Series Liquid Turbine Flow MeterStandard Flow Range Extended Extended MaxStandard Flow Inches Range BBL/Hr BPH w/20% Range M 3/HrNominal K-Factor Size Pulses/BBL Pulses/M Pulses/US Gal Rangeability of Liquid Turbine Flow Meters = 1 .7 to Meter Size Minimum Linear Maximum Linear BBL/Hr Meter Performance in High Viscosity Liquids Sizing RatioInstallation and Operating Recommendations Small Diameter Meter TubeBack Pressure Effects of Back PressurePickoff Specifications Turbine Meter InstrumentationPage Stirling, Scotland Europe, Middle East, Africa