Altinex DA1931CT manual Diagram 4 DIP-SWITCH Settings, Position Description

Page 10

SPECIAL APPLICATION

DIAGRAM 4: DIP-SWITCH SETTINGS

The DA1931CT has an internal Dip-Switch with 6 positions to achieve the following features:

Position

Description

1

Video Gain (G=1/G=2)

2

Factory Default = OFF (G=2).

Sync on Green (ON/OFF)

Factory Default = OFF

3, 4 HSync Polarity (Positive/Negative)

3 ON, 4 OFF = Positive (Factory Default)

3 OFF, 4 ON = Negative

5, 6 VSync Polarity (Positive/Negative)

5 OFF, 6 ON = Positive (Factory Default)

5 ON, 6 OFF = Negative

C-VIDEO

LOOP 2

 

S-VIDEO

LOOP 1

 

INPUT

RGBHV/

 

YPbPr

 

 

POWER

AUDIO

 

 

VIDEO EQ

AUDIO

 

400-0199-006

9

Image 10
Contents DA1931CT Table of Contents Cleaning Precautions / Safety WarningsInstallation GeneralTechnical Specifications About Your DA1931CTDA1931CT Mechanical Product Description Application Diagrams Diagram 1 Typical SetupDiagram 2 RJ-45 Pinout Pin Number RJ-45 Output SignalsDiagram 3 Internal View Twisted Pair to Video + Audio ReceiverDiagram 4 DIP-SWITCH Settings Position DescriptionOperation Installing Your DA1931CTTroubleshooting Guide Video EqualizationLED is not Green Limited WARRANTY/RETURN PoliciesAltinex Policies No Sound