Graco 309572ZAF important safety instructions 15F144 Hose Wire Jumper, Fluid Temperature

Page 30

Parts

15F144 Hose Wire Jumper

Use the 15F144 Hose Wire Jumper to heat only the major volume hose, in a wide ratio system.

To build one complete 50 ft single side heated hose bundle, order the following parts:

Ref.

Part

Description

Qty

100

15F144

JUMPER, hose wire

1

101

 

HOSE, resin, heated; 50 ft

1

 

 

(15.2 m) minimum; see tables

 

 

 

starting on page 4

 

102

24J523

CABLE, FTS

1

104

261670

FLUID TEMPERATURE

1

 

 

SENSOR; see page 25

 

105

pur-

HOSE, hardener, unheated; 50

1

 

chase

ft (15.2 m) minimum; customer

 

 

locally

supplied

 

106

pur-

CONNECTORS, fluid; as

as

 

chase

required to complete assem-

req’d

 

locally

bly; not shown

 

Install as follows:

This hose must be used with an FTS and cable to provide grounding.

1.Wrap hose wire jumper (100) around resin hose (101) in a spiral fashion.

2.Connect resin hose wire (101a) to other side of Power-Lock connector (100a); see page 13.

3.Wrap FTS cable (102) around resin hose

(101)in a spiral fashion.

4.Twist hoses (101 and 105) together to pro- vide strain relief.

5.Repeat steps 1-4for each length of hose

(101).Connect hoses, electrical connec- tors, and cables; see Connect Heated Hoses, page 13.

6.Install one -Lock connector (100a) between wires; see page 13.

7.Connect FTS with a Non-Heated Whip Hose or Remote Mix Manifold, page 20.

30

309572ZAF

Image 30
Contents Power-LockHeated Hose Important Safety instructionsContents Power-Lock Hose Bundle Part Numbers Whip HosesAdapter Fittings Standard 2 Component Hose RTD 2-Component Hose for use with GCA Controlled ReactorsGuard Cable Outlet m Red Hose Blue Hose Airless 2 Component HoseCustom Application 2 Component Hose In. mm Standard Hose Fittings Braided LengthSide Inlet Outlet FTS Probe Psi 34.5 MPa, 345 bar Fluid Temperature Sensor FTS KitsFTS kits contain SideElectric Shock Hazard Toxic Fluid or Fumes Hazard Isocyanate Conditions Material Self-ignitionKeep Components a and B Separate Moisture Sensitivity Isocyanates Foam Resins with 245 fa Blowing AgentsChanging Materials Installation DescriptionConnect Whip Hose to Gun or Gun Manifold Connect Heated Hoses Strip Length Incorrect CorrectInsert Wire and Setscrew For non-RTD hoses only, connect cables Installation 309572ZAF Connect FTS and Heated Dual Whip Hose For 1/2 in mm ID fluid hosesSee Check Hoses for Leaks, Non-RTD Hoses RTD 2-Component HosesProportioner To Mix Manifold or non-heated whip hose Check Hoses for Leaks Protective Covering Fluid Temperature Sensor FTS Calibration OperationMaintenance Instructions for Replacing Individual a or B HoseParts Using 261669 Fluid Temperature Sensor JIC to JIC fittingsWhip Hose Fluid Temperature Sensor Heated Fluid HoseUsing 24M943 Fluid Temperature Sensor NPT to NPT fittings Ref. Part Description Qty Fluid Temperature Sensor Whip Hose CouplerHOSE, air 3.75 in .3 mm Using 261670 Fluid Temperature Sensor JIC to NPT fittings Fluid Temperature Sensor Heated Fluid HosePart Description Qty 15F144 Hose Wire Jumper Fluid TemperatureSingle Side Heated Tap Terminal Hose Length, ft m Label ft Accessories Scuff GuardPart Description Whip Hose Maximum Fluid Working Pressure Technical DataPower-Lock Heated Hose Metric Standard 2 Component Hose Maximum Fluid Working PressureAirless 2 Component Hose Maximum Fluid Working Pressure FTS Maximum Fluid Working PressureFTS For GCA Systems Maximum Fluid Working Pressure Technical Data 309572ZAF Graco Standard Warranty Graco InformationUtor closest to you 1-800-328-0211 Toll Free