Canon N656U, N1220U, N650U manual Installing Plug-in Module CS-U, Operating Environment

Page 6

Installing Plug-in Module CS-U

Please install Plug-in Module CS-U with the other application programs according to the instructions in the “1. Installing the Software” section of “Chapter 3, Using the Macintosh Platform,” of the Getting Started guide supplied with the scanner.

Operating Environment

Hardware

Power Macintosh or iMac with built-in USB ports (performance on Macintosh compatibles is not guaranteed)

Main Memory

• 32 MB or more (64 MB or more recommended)

Application Software

CanoScan Toolbox CS

ArcSoft PhotoStudio 2000

Other plug-in compatible application programs

Display

256 colors or more (32,000 colors or more recommended; black & white or 4-tone monochrome monitors are not supported)

System Software

Mac OS 8.5 or higher (First-generation, Bondi blue iMacs may require a system upgrade and an update to the system and firmware.*)

*For information about upgrades and updating for iMacs, refer to the Troubleshooting menu on the CanoScan Setup Utility CD-ROM. Look for the “Scanner won’t work on an iMac” item in the topic entitled “Problems with the Scanner.”

Caution

• The ColorSyncTM Profiles file is installed along with Plug-in Module CS-U. ColorSyncTM Ver. 2.0 or higher is required to use these profiles with the automatic color matching system (p. 49).

The following display profile files are available: CANON gamma 1.5 monitor, CANON gamma 1.8 monitor and CANON gamma 2.1 monitor. If you wish to adjust the color balance of the display, double-click [ColorSync™] in your Macintosh’s Control Panels folder and select one of these display profiles.

6

Image 6
Contents Users Guide How to Make Best Use of the Manuals When you open the boxHow to Use this Guide Where to LookAbout the Conventions Used in this Guide Table of Contents Adjusting Scanned Images Installing Plug-in Module CS-U Operating EnvironmentControl Panel Features Image Size ppScanning Procedures E PGamma Curve Adjusts Image Brightness Plug-in Module CS-U Special FeaturesSee the Results of Adjustments Immediately Dynamic Preview ColorSync Ver 2.0 + Compatible for Auto Tone CorrectionStart Plug-in Module CS-U Install Plug-in Module CS-UQuick Start Instructions Position materials for scanning and preview themClick on the Browser button Selection frame will appear Verify Image Quality with the Browser Function beforeSpecify the Area of the Image to be Scanned Select the area to be scanned by clicking and draggingScan the Image p Save the Scanned Image pE P Displaying the Plug-in Module CS-U Control Panel RGB ValuesOperating Procedures Procedures Positioning OriginalsPlace the original on the scanners document glass Previewing Click on the Preview buttonSelecting the Output Device Setting the Resolution and Magnification Output Device Resolution= 720 dpi, Magnification= 100%To Set the Magnification Factor Set the desired magnification factor on the control panelGrayscale Setting the Scan ModeBlack and White Color DocumentsClick the arrow beside Scan Mode Select a scan mode from the pop-up menuVerifying the Image before Scanning To Verify the ImageRotating the Image Use these buttons to rotate the imageSetting Preferences Output DeviceAspect Ratio Unit Preview WindowReset Default Settings CalibrationClose Plug-in After Scan Operating Procedures Scanning Setting the Scan Area Position the pointer in the preview windowProcedures to Zoom ZoomingSelect the area you want to enlarge with the zoom function Click on the Zoom In button Specify the Scan Area ScanningTo Initiate the Scan Click on the Scan buttonSaving Scanned Images Enter a name for the file and click the Save buttonGrayscale, Color Photos and Color Documents Black & WhiteColor Photos and Color Documents Tone Adjustment Tone Adjustment DialogHistogram Settings How to Interpret HistogramsTo Adjust a Histogram How to Adjust HistogramsClick on the OK button Shadow MarkTone Curve Settings Manipulating the GraphTo Edit the Tone Curve Click the OK buttonRelationship Between the Tone Curve Image Brightness Value =Brightness and Contrast Settings ContrastBrightness To Adjust the Brightness and Contrast Adjusting the Color Balance Operating ProcedureGamma Value Settings Matching the Gamma Value to the Display CharacteristicsGamma value To Change the Gamma Value Settings Adjusting the Threshold Value To Set the Threshold ValueStandard Auto Tone CorrectionTo Set the Auto Tone Correction ColorSyncUnsharp Mask Open the Image menu and select Unsharp MaskDescreen Open the Image menu and select DescreenSaving/Recalling Settings To Save Settings in a Settings FileClick the Save button To Recall a Settings File Matching Scan Resolution to Purpose Optical and Enhanced ResolutionsScanning Techniques Appendices Troubleshooting Problem Scan button cannot be selected Cause Error MessagesError Message ResponseBits/Bit Numbers GlossaryAuto Tone Correction Black Eyedropper ToolColor Channel DotHistogram Image FileMagnification Moiré Optical ResolutionResolution PixelThreshold Value Scan ModeShadows Tone CurveIndex Output device 7, 11, 18, 25Page Canon Customer Support Help Desk Canon Computer SYSTEMS, INCOE-040AA 052000 CDS Canon Inc