Canon N1220U, N656U, N650U manual Setting the Resolution and Magnification

Page 19

S T E P 1

Setting the Resolution and Magnification

The magnification of an image can be changed before scanning to accommodate reproductions that are larger or smaller than the original. The settings can be changed in increments of 1%.

6"/15cm

4"/10cm

 

12"/30cm

Scanning at 200%

 

Scanning with horizontal/

 

vertical 2x magnification

 

Scanning at 50%

3"/7.5cm

Scanning with horizontal/

2"/5cm

 

vertical 0.5x magnification

 

8"/20cm

Changing the magnification setting causes the resolution display on the control panel to change correspondingly. This resolution setting is referred to as the “scanning resolution.”

Output Device Resolution= 720 dpi, Magnification= 100%

Magnification

changed to

Magnification Scanning Resolution

50%

The scanning resolution changes accordingly.

Hint

Magnification and Resolution

Why does the image size change with the magnification? Let us answer this with an example using a “BJ (720 dpi)” output device. If you were to scan an image with this device setting and set the magnification factor to 50%, the scanning resolution will automatically change to 360 dpi. At this setting, the image will be scanned at a resolution of 360 dpi and the output device will convert this to 720 dpi, shrinking the size of the output in the process because it will only have half the data with which to fill the space.

 

 

Image size = 5"x5"

Image size = 2.5"x2.5"

 

 

(12.7 x 12.7cm)

 

 

(6.35 x 6.35cm)

Magnification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50%

 

 

 

 

 

 

 

 

 

Scanned at

 

 

Output device

 

 

 

 

 

 

 

 

360 dpi

 

 

 

corrects to

 

 

 

 

 

 

720 dpi

 

 

 

 

 

 

19

Image 19
Contents Users Guide When you open the box How to Make Best Use of the ManualsWhere to Look How to Use this GuideAbout the Conventions Used in this Guide Table of Contents Adjusting Scanned Images Operating Environment Installing Plug-in Module CS-UImage Size pp Control Panel FeaturesE P Scanning ProceduresColorSync Ver 2.0 + Compatible for Auto Tone Correction Plug-in Module CS-U Special FeaturesSee the Results of Adjustments Immediately Dynamic Preview Gamma Curve Adjusts Image BrightnessPosition materials for scanning and preview them Install Plug-in Module CS-UQuick Start Instructions Start Plug-in Module CS-USelect the area to be scanned by clicking and dragging Verify Image Quality with the Browser Function beforeSpecify the Area of the Image to be Scanned Click on the Browser button Selection frame will appearSave the Scanned Image p Scan the Image pE P RGB Values Displaying the Plug-in Module CS-U Control PanelOperating Procedures Positioning Originals ProceduresPlace the original on the scanners document glass Click on the Preview button PreviewingSelecting the Output Device Output Device Resolution= 720 dpi, Magnification= 100% Setting the Resolution and MagnificationSet the desired magnification factor on the control panel To Set the Magnification FactorColor Documents Setting the Scan ModeBlack and White GrayscaleSelect a scan mode from the pop-up menu Click the arrow beside Scan ModeTo Verify the Image Verifying the Image before ScanningUse these buttons to rotate the image Rotating the ImageOutput Device Setting PreferencesAspect Ratio Preview Window UnitCalibration Reset Default SettingsClose Plug-in After Scan Operating Procedures Scanning Position the pointer in the preview window Setting the Scan AreaZooming Procedures to ZoomSelect the area you want to enlarge with the zoom function Click on the Zoom In button Click on the Scan button ScanningTo Initiate the Scan Specify the Scan AreaEnter a name for the file and click the Save button Saving Scanned ImagesBlack & White Grayscale, Color Photos and Color DocumentsColor Photos and Color Documents Tone Adjustment Dialog Tone AdjustmentHow to Interpret Histograms Histogram SettingsHow to Adjust Histograms To Adjust a HistogramShadow Mark Click on the OK buttonManipulating the Graph Tone Curve SettingsClick the OK button To Edit the Tone CurveValue = Relationship Between the Tone Curve Image BrightnessContrast Brightness and Contrast SettingsBrightness To Adjust the Brightness and Contrast Operating Procedure Adjusting the Color BalanceMatching the Gamma Value to the Display Characteristics Gamma Value SettingsGamma value To Change the Gamma Value Settings To Set the Threshold Value Adjusting the Threshold ValueColorSync Auto Tone CorrectionTo Set the Auto Tone Correction StandardOpen the Image menu and select Unsharp Mask Unsharp MaskOpen the Image menu and select Descreen DescreenTo Save Settings in a Settings File Saving/Recalling SettingsClick the Save button To Recall a Settings File Optical and Enhanced Resolutions Matching Scan Resolution to PurposeScanning Techniques Appendices Troubleshooting Problem Scan button cannot be selected Response Error MessagesError Message CauseBlack Eyedropper Tool GlossaryAuto Tone Correction Bits/Bit NumbersDot Color ChannelImage File HistogramMagnification Pixel Optical ResolutionResolution MoiréTone Curve Scan ModeShadows Threshold ValueOutput device 7, 11, 18, 25 IndexPage Canon Computer SYSTEMS, INC Canon Customer Support Help DeskOE-040AA 052000 CDS Canon Inc