Peavey PV 215 EQ manual IEC Mains Connector, Ground Lift Switch, XLR Input, XLR Output

Page 9

R E A R PA N E L

10

9

10

9

8

7

IEC MAINS CONNECTOR (7)

This is a standard IEC power connector. An AC mains cord having the appropriate AC plug and ratings for the intended operating voltage is included in the carton.

Never break off the ground pin on any equipment. It is provided for your safety. If the outlet used does not have a ground pin, a suitable grounding adapter should be used and the third wire should be grounded properly. To prevent the risk of shock or fire hazard, always make sure that the equalizer and all associated equipment is properly grounded.

Incorporated into this IEC MAINS CONNECTOR is the MAINS FUSE HOLDER. If for any reason you are unable to power up this unit, remove the fuse by pulling out the holder. Check to see if the fuse is operational. If not, then replace with a fuse of the appropriate value and rating. If the fuse continues to fail contact your nearest Certified Peavey Service Center.

GROUND LIFT SWITCH (8)

This will lift the circuit ground while keeping the Mains Safety Ground intact.This is useful when hum is present, and will maintain a safely operated unit.

XLR INPUT (9)

These female 3-pin connectors provide balanced input when used with male XLR connectors.

XLR OUTPUT (10)

These male 3-pin connectors provide balanced output when used with female XLR connectors.

9

Image 9
Contents PV215 EQ Graphic Equalizer Page Sound Level dBA, Slow Response Important Safety InstructionsWichtige Sicherheitshinweise Bewahren SIE Diese Sicherheitshinweise AUFInstructions Importantes DE Securite Gardez CES InstructionsInstrucciones Importantes Para SU Seguridad English FeaturesDescription Equalization ProcessLevel LED Meter PowerLevel Control Equalizer SectionGround Lift Switch IEC Mains ConnectorXLR Input XLR OutputChannels PV215EQ Graphic EqualizerBeschreibung DeutschMerkmale AbgleichPegelregler LED-PEGELMESSEREQUALIZER-STUFE TiefpassfilterGROUND-LIFT-SCHALTER IEC-NETZSTECKERKanäle Technische DatenFrançais CaractéristiquesLe procédé d’égalization Section D’EGALISATION Controle DE NiveauFiltre COUPE-BAS Interrupteur DE Mise EN Veille BypassInterrupteur DE Correspondance DE Masse Ground Lift Connecteur D’ALIMENTATION IECEntree XLR Sortie XLRCanaux PV215EQ Egaliseur GraphiqueDescripción EspañolCaracterísticas Proceso de EcualizaciónControl DE Nivel Medidor LED DEL Nivel DE SalidaSección DEL Ecualizador Filtro DE Recorte DE GravesInterruptor DE Encendido DE Tierra Conector Principal DE CorrienteEntrada XLR Salida XLRCanales Ecualizador Gráfico PV215EQPeavey Electronics Corporation Limited Warranty