Pelco C3453M-B manual Installing the SUN Shroud, Gland Cable Diameter, Model Number Input Voltage

Page 10

INSTALLING THE SUN SHROUD

The optional sun shroud fits over the top of the EH1512 enclosure. Perform the following steps to install the sun shroud.

1.Position the front of the sun shroud above the front of the enclosure.

2.Press the sun shroud down and against the enclosure until the sun shroud snaps into place. Table A. Allowable Cable Diameter

Gland

Cable Diameter

 

 

PG9

0.181-inch to 0.312-inch

 

 

PG11

0.230-inch to 0.395-inch

 

 

NOTE: Conduit must be used if the cable diameter is greater than 0.395 inches (1.00 cm). RG11 coaxial might be greater than 0.395 inches.

Table B describes the minimum recommended cable sizes needed for use with the heater and blower combinations in the EH1512 enclosure.

WARNING: When using a single power source for both camera and accessories, consider the camera power consumption when determining the wire gauge. Table B does not include camera power.

Table B. Enclosure Accessory Wiring Distances

 

 

Maximum Power

 

 

Model Number

Input Voltage

Consumption

Cable Size

Cable Distance

 

 

 

 

 

 

 

 

20 AWG

2,782 ft (848 m)

EH1512-1

120 VAC

22 W

18 AWG

4,424 ft (1,348 m)

16 AWG

7,035 ft (2,144 m)

 

 

 

 

 

 

14 AWG

11,184 ft (3,409 m)

 

 

 

 

 

 

 

 

20 AWG

142 ft (43 m)

EH1512-2

24 VAC

22 W

18 AWG

225 ft (69 m)

16 AWG

358 ft (109 m)

 

 

 

 

 

 

14 AWG

569 ft (173 m)

 

 

 

 

 

 

 

 

20 AWG

6,473 ft (1,973 m)

EH1512-3

230 VAC

22 W

18 AWG

10,291 ft (2,137 m)

16 AWG

16,365 ft (4,988 m)

 

 

 

 

 

 

14 AWG

26,019 ft (7,931 m)

 

 

 

 

 

 

 

 

20 AWG

2,782 ft (848 m)

EH1512-1MT,

120 VAC

22 W

18 AWG

4,424 ft (1,348 m)

EH1512-1MTS

16 AWG

7,035 ft (2,144 m)

 

 

 

 

 

14 AWG

11,184 ft (3,409 m)

 

 

 

 

 

 

 

 

20 AWG

142 ft (43 m)

EH1512-2MT,

24 VAC

22 W

18 AWG

225 ft (69 m)

EH1512-2MTS

16 AWG

358 ft (109 m)

 

 

 

 

 

14 AWG

569 ft (173 m)

 

 

 

 

 

 

 

 

20 AWG

6,473 ft (1,973 m)

EH1512-3MT,

230 VAC

22 W

18 AWG

10,291 ft (2,137 m)

EH1512-3MTS

16 AWG

16,365 ft (4,988 m)

 

 

 

 

 

14 AWG

26,019 ft (7,931 m)

 

 

 

 

 

10

C3453M-B (4/09)

Image 10
Contents EH1512 Series Enclosures List of Illustrations ContentsList of Tables Present within this unit Important Safety InstructionsLiterature accompanying this unit Description ModelsPackage Contents Installation Installing the Camera and MountC3453M-B 4/09 C3453M-B 4/09 EH1512 Wiring Diagram Gland Cable Diameter Installing the SUN ShroudModel Number Input Voltage Wire Gauge Total VA MaintenanceTable C VAC Wiring Distances Cable Type Maximum DistanceMechanical SpecificationsModels GeneralOptional Accessories Recommended MountsCameras Recommended Cameras and LensesLenses Product Warranty and Return Information Warranty