Pelco IV SE manual 211

Page 17

Table B. Switch Settings for SW1 D-Type Control (Continued)

SPECTRA

 

 

 

SWITCH SETTING

 

 

 

 

 

 

 

 

 

 

 

ADDRESS

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

SW1-6

SW1-7

SW1-8

 

211

ON

ON

OFF

OFF

ON

OFF

ON

ON

 

 

 

 

 

 

 

 

 

212

OFF

OFF

ON

OFF

ON

OFF

ON

ON

213

ON

OFF

ON

OFF

ON

OFF

ON

ON

 

 

 

 

 

 

 

 

 

214

OFF

ON

ON

OFF

ON

OFF

ON

ON

215

ON

ON

ON

OFF

ON

OFF

ON

ON

 

 

 

 

 

 

 

 

 

216

OFF

OFF

OFF

ON

ON

OFF

ON

ON

217

ON

OFF

OFF

ON

ON

OFF

ON

ON

 

 

 

 

 

 

 

 

 

218

OFF

ON

OFF

ON

ON

OFF

ON

ON

219

ON

ON

OFF

ON

ON

OFF

ON

ON

 

 

 

 

 

 

 

 

 

220

OFF

OFF

ON

ON

ON

OFF

ON

ON

221

ON

OFF

ON

ON

ON

OFF

ON

ON

 

 

 

 

 

 

 

 

 

222

OFF

ON

ON

ON

ON

OFF

ON

ON

223

ON

ON

ON

ON

ON

OFF

ON

ON

 

 

 

 

 

 

 

 

 

224

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

225

ON

OFF

OFF

OFF

OFF

ON

ON

ON

 

 

 

 

 

 

 

 

 

226

OFF

ON

OFF

OFF

OFF

ON

ON

ON

227

ON

ON

OFF

OFF

OFF

ON

ON

ON

 

 

 

 

 

 

 

 

 

228

OFF

OFF

ON

OFF

OFF

ON

ON

ON

229

ON

OFF

ON

OFF

OFF

ON

ON

ON

 

 

 

 

 

 

 

 

 

230

OFF

ON

ON

OFF

OFF

ON

ON

ON

231

ON

ON

ON

OFF

OFF

ON

ON

ON

 

 

 

 

 

 

 

 

 

232

OFF

OFF

OFF

ON

OFF

ON

ON

ON

233

ON

OFF

OFF

ON

OFF

ON

ON

ON

 

 

 

 

 

 

 

 

 

234

OFF

ON

OFF

ON

OFF

ON

ON

ON

235

ON

ON

OFF

ON

OFF

ON

ON

ON

 

 

 

 

 

 

 

 

 

236

OFF

OFF

ON

ON

OFF

ON

ON

ON

237

ON

OFF

ON

ON

OFF

ON

ON

ON

 

 

 

 

 

 

 

 

 

238

OFF

ON

ON

ON

OFF

ON

ON

ON

239

ON

ON

ON

ON

OFF

ON

ON

ON

 

 

 

 

 

 

 

 

 

240

OFF

OFF

OFF

OFF

ON

ON

ON

ON

241

ON

OFF

OFF

OFF

ON

ON

ON

ON

 

 

 

 

 

 

 

 

 

242

OFF

ON

OFF

OFF

ON

ON

ON

ON

243

ON

ON

OFF

OFF

ON

ON

ON

ON

 

 

 

 

 

 

 

 

 

244

OFF

OFF

ON

OFF

ON

ON

ON

ON

245

ON

OFF

ON

OFF

ON

ON

ON

ON

 

 

 

 

 

 

 

 

 

C3412M (9/06)

17

Image 17
Contents Spectra IV Spectra IV SE Series Dome Drives Page Contents Blank All Above/Blank All Below Activate Aux Current Reading Reset Alert Welcome Switch Settings InstallationSW2 Switches 1-3 Special System Settings SW1 Receiver AddressSW2 Switches 6-8 Baud Settings SW2 Switches 4-5 Serial Port SettingsDome Drive Installation Dome Drive InstallationTable A. Switch Settings for SW1 P-Type Control Spectra Switch Setting Address Table B. Switch Settings for SW1 D-Type ControlTable B. Switch Settings for SW1 D-Type Control 100 106 141 176 211 246 Getting Started Configure DoneHow to Operate Your Dome System Quick Programming Guide Accessing Main Menu PresetPress the Spot Monitor key CM9500NET300/NET350/NET4001A 16X LowLight Color Menu Tree Dome Settings Camera 22X EXview LowLight Black-White Menu Tree Reference Information Azimuth Elevation Zoom 22X EXview LowLight Color Menu Tree Alarm Settings AUX Alarm Number AUX 1 Mode 23X LowLight Day/Night Menu Tree Line Sync Presets Edit Detection Areas Preset Number 35X LowLight Day/Night Menu Tree Uvwxy Date Format MM/DD/YYYY Edit Event Label Language Exit Additional System InformationDisplay Setup Label Positions Camera Dome SettingsType of Lighting Auto Focus16X Models DD4TC16 and DD4TC16-X Zoom LimitLOW Light Limit Zoom SpeedHigh LOWDark IR CUT FilterShutter Speed Advanced Camera SettingsAGC Limit Numeric ValueAuto Iris Auto iris is disabled, and control is always manualDetermined by the auto iris level setting Auto Sharpness Level. Sharpness level settings range fromAuto White Balance GainBacklight Compensation BLC There are two backlight compensation settingsOFF default Wide Dynamic Range Video LevelSet the video output to one of the following NormalApplies only to 35X models Electronic Image StabilizationThere are two auto flip modes On default Motion SettingsAuto Flip Proportional PANPark Time PresetAuto Scan Frame ScanThere are three preset freeze frame settings Preset Freeze FrameScan Speed Image is never frozenManual Limit StopsScan Stop is reachedAzimuth Zero None Power UPPower UP Action Dome synchronizes to the internal clock Settings range from 0-359 degreesLine Sync Spectra PresetsFollowing presets are predefined for specific functions Becomes C3412M 9/06 Edit Detection Areas Enable Motion DetectionMotion Detection Areas Triggers a command to AUX Activate AUX CommandAUX Time Edit SchedulePatterns Zones To set a window blanking area Window BlankingClear Window ReverseBlanks everything below a user-defined tilt angle Blank ALL ABOVE/BLANK ALL belowReset Delay AlarmsResume SequenceMEDIUM/LOW Normally open Momentary AUXLatching Edit Title Text Title TextRepeat AlertACK Action Reset AlertActivate AUX Current ReadingClear Password Fixed Date Power LineClock Repeat steps b-d for the ending date and time Follow the instructions in for Fixed DATE, adding Week Event Label EventEvent Type Edit Event Label Edit Event LabelHolidays have no effect on the event Edit EventDate is in the list of holidays Holiday Clear EventList Event April Edit HolidayHoliday occurs on the same date each year List Holidays Clear HolidayUse this page to record scheduled events Scheduled EventsReset Camera Reset, Cycle Power, RebootCycle Camera Power Reboot SystemSoftware/Language File Upload Suggested Preventative Maintenance 16X Models SpecificationsNtsc PAL3.9/6.3 seconds 22X Models MonochromeLux at 1/2 sec. shutter speed Lux at 1/1.5 sec. shutter speedDD4C22 22X Models ColorInterlace Inch CCD 23X ModelsLux at 1/1.5 sec. shutter speed B-W Zoom Speed 4.2/5.8 seconds Horizontal Angle of ViewLux at 1/50 sec. shutter speed B-W DD4CBW35 35X ModelsLux at 1/3 sec. shutter speed color Zoom Speed 4.6/6.6 seconds Horizontal Angle of ViewLux at 1/50 sec. shutter speed color Product Warranty and Return Information ISO9001
Related manuals
Manual 80 pages 19.54 Kb

IV SE specifications

The Pelco IV SE is a leading-edge camera system designed specifically for surveillance applications that demand high-quality imaging, flexibility, and robustness. With its sleek design and advanced features, the Pelco IV SE is an essential tool for security professionals aiming to enhance situational awareness and improve monitoring capabilities.

One of the key features of the Pelco IV SE is its impressive image quality. The camera is equipped with advanced image sensors that provide high resolution and clarity, ensuring that critical details are captured even in challenging lighting conditions. Its enhanced low-light performance enables efficient operation in darkness, making it suitable for both day and night surveillance tasks.

In terms of technology, the Pelco IV SE incorporates advanced video compression algorithms, such as H.264 and H.265. These technologies allow for efficient bandwidth utilization while maintaining video quality, enabling long-term storage of data without sacrificing clarity. The camera also supports Power over Ethernet (PoE), simplifying installation by allowing power and data to be transmitted over a single cable, reducing clutter and setup complexity.

Another standout characteristic is its flexibility. The Pelco IV SE is designed for various mounting options, including wall, ceiling, and pole mounts, making it adaptable for different environments and surveillance needs. The camera features a varifocal lens, allowing users to adjust the field of view to capture images from different distances, thus optimizing surveillance coverage.

Additionally, the Pelco IV SE integrates seamlessly with existing security systems, providing compatibility with various video management software platforms. This interoperability ensures that users can incorporate the camera into their broader security infrastructure without significant disruption.

The device also comes with intelligent video analytics capabilities, such as motion detection and facial recognition, enhancing its functionality. These features allow for proactive monitoring, where alerts can be set up for suspicious activities, ensuring timely responses to potential threats.

With its robust construction, the Pelco IV SE is built to withstand harsh environmental conditions. It adheres to specific IP ratings, indicating its resistance to dust and water, making it an ideal choice for both indoor and outdoor surveillance applications. In summary, the Pelco IV SE is a versatile, high-performance camera that combines advanced imaging capabilities, reliable technology, and extensive adaptability to meet the evolving demands of modern security surveillance.