Pelco IV SE manual ACK Action, Activate AUX, Current Reading, Reset Alert

Page 72

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP>

<DOME SETTINGS> ACK ALERT

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING> <ALARMS>

<AUX>

<TITLE TEXT> <ALERT> <CLEAR> <PASSWORD> <CLOCK> <EVENT>

BACK

EXIT

ALERT

REPEAT ACK ACTION ACTIVATE AUX <CURRENT READING> RESET ALERT

BACK

EXIT

CURRENT READING

TEMPERATURE

DEWPOINT

PRESSURE

REFRESH

BACK

EXIT

ACK ACTION

Acknowledge action programs the alert label behavior after the alert condition has been acknowledged. The following settings are available for acknowlegde:

ALWAYS ON

The alert label is displayed until alert conditions are cleared.

OFF 8 HRS

The alert label is turned off for 8 hours. Label returns after 8 hours if the alert

 

condition persists.

OFF 24 HRS

The alert label is turned off for 24 hours. Label returns after 24 hours if the alert

 

condition persists.

OFF 48 HRS

The alert label is turned off for 48 hours. Label returns after 48 hours if the alert

 

condition persists.

ACTIVATE AUX

This setting activates an auxiliary when an alert condition exists. Settings include the following:

NONE (default) Not activated.

1An alert condition will close AUX 1.

2An alert condition will close AUX 2.

CURRENT READING

The Current Reading menu displays the existing status of temperature, pressure, and dew point inside the dome system. An arrow displayed to the left of a menu item denotes that an alert condition exists.

An up arrow indicates the reading is over the threshold. A down arrow indicates the reading is below the threshold.

The high temperature alert occurs if the temperature is above 140°F (60°C).

The low temperature alert occurs if the temperature is below -40°F (-40°C).

The high pressure alert occurs if the pressure is above 13 PSIG.

The low pressure alert occurs if the pressure is below 1 PSIG.

The dew point (high humidity) alert occurs if the difference between the temperature and the dew point is less than or equal to 3°C.

NOTE: The normal operating temperature inside the unit will be greater than the temperature outside the back box due to the heat emitted by the system’s electronics.

RESET ALERT

Reset alert clears the alert condition and removes the alert label from the monitor. The system automatically checks internal conditions 60 seconds after reset. If conditions are still unacceptable, the alert label reappears on the screen indicating further corrective action is required.

72

C3412M (9/06)

Image 72
Contents Spectra IV Spectra IV SE Series Dome Drives Page Contents Blank All Above/Blank All Below Activate Aux Current Reading Reset Alert Welcome Installation Switch SettingsSW2 Switches 1-3 Special System Settings SW1 Receiver AddressSW2 Switches 4-5 Serial Port Settings SW2 Switches 6-8 Baud SettingsDome Drive Installation Dome Drive InstallationTable A. Switch Settings for SW1 P-Type Control Table B. Switch Settings for SW1 D-Type Control Spectra Switch Setting AddressTable B. Switch Settings for SW1 D-Type Control 100 106 141 176 211 246 Configure Done Getting StartedHow to Operate Your Dome System Accessing Main Menu Preset Quick Programming GuideCM9500 Press the Spot Monitor keyNET300/NET350/NET4001A 16X LowLight Color Menu Tree Dome Settings Camera 22X EXview LowLight Black-White Menu Tree Reference Information Azimuth Elevation Zoom 22X EXview LowLight Color Menu Tree Alarm Settings AUX Alarm Number AUX 1 Mode 23X LowLight Day/Night Menu Tree Line Sync Presets Edit Detection Areas Preset Number 35X LowLight Day/Night Menu Tree Uvwxy Date Format MM/DD/YYYY Edit Event Label Language System Information Exit AdditionalDisplay Setup Label Positions Dome Settings CameraType of Lighting Auto FocusZoom Limit 16X Models DD4TC16 and DD4TC16-XZoom Speed LOW Light LimitHigh LOWIR CUT Filter DarkAdvanced Camera Settings Shutter SpeedAGC Limit Numeric ValueAuto iris is disabled, and control is always manual Determined by the auto iris level settingAuto Iris Level. Sharpness level settings range from Auto SharpnessAuto White Balance GainThere are two backlight compensation settings OFF defaultBacklight Compensation BLC Video Level Wide Dynamic RangeSet the video output to one of the following NormalElectronic Image Stabilization Applies only to 35X modelsMotion Settings There are two auto flip modes On defaultAuto Flip Proportional PANPreset Park TimeAuto Scan Frame ScanPreset Freeze Frame There are three preset freeze frame settingsScan Speed Image is never frozenLimit Stops ManualScan Stop is reachedAzimuth Zero Power UP Power UP ActionNone Settings range from 0-359 degrees Line SyncDome synchronizes to the internal clock Presets Following presets are predefined for specific functionsSpectra Becomes C3412M 9/06 Enable Motion Detection Edit Detection AreasMotion Detection Areas Activate AUX Command Triggers a command to AUXAUX Time Edit SchedulePatterns Zones Window Blanking To set a window blanking areaReverse Clear WindowBlank ALL ABOVE/BLANK ALL below Blanks everything below a user-defined tilt angleAlarms Reset DelayResume SequenceMEDIUM/LOW Normally open AUX LatchingMomentary Title Text Edit Title TextAlert RepeatReset Alert ACK ActionActivate AUX Current ReadingClear Password Power Line ClockFixed Date Repeat steps b-d for the ending date and time Follow the instructions in for Fixed DATE, adding Week Event Event TypeEvent Label Edit Event Label Edit Event LabelEdit Event Date is in the list of holidaysHolidays have no effect on the event Clear Event List EventHoliday Edit Holiday Holiday occurs on the same date each yearApril Clear Holiday List HolidaysScheduled Events Use this page to record scheduled eventsReset, Cycle Power, Reboot Reset CameraCycle Camera Power Reboot SystemSoftware/Language File Upload Suggested Preventative Maintenance Specifications 16X ModelsNtsc PAL22X Models Monochrome 3.9/6.3 secondsLux at 1/2 sec. shutter speed Lux at 1/1.5 sec. shutter speed22X Models Color DD4C2223X Models Interlace Inch CCDZoom Speed 4.2/5.8 seconds Horizontal Angle of View Lux at 1/50 sec. shutter speed B-WLux at 1/1.5 sec. shutter speed B-W 35X Models DD4CBW35Zoom Speed 4.6/6.6 seconds Horizontal Angle of View Lux at 1/50 sec. shutter speed colorLux at 1/3 sec. shutter speed color Product Warranty and Return Information ISO9001
Related manuals
Manual 80 pages 19.54 Kb

IV SE specifications

The Pelco IV SE is a leading-edge camera system designed specifically for surveillance applications that demand high-quality imaging, flexibility, and robustness. With its sleek design and advanced features, the Pelco IV SE is an essential tool for security professionals aiming to enhance situational awareness and improve monitoring capabilities.

One of the key features of the Pelco IV SE is its impressive image quality. The camera is equipped with advanced image sensors that provide high resolution and clarity, ensuring that critical details are captured even in challenging lighting conditions. Its enhanced low-light performance enables efficient operation in darkness, making it suitable for both day and night surveillance tasks.

In terms of technology, the Pelco IV SE incorporates advanced video compression algorithms, such as H.264 and H.265. These technologies allow for efficient bandwidth utilization while maintaining video quality, enabling long-term storage of data without sacrificing clarity. The camera also supports Power over Ethernet (PoE), simplifying installation by allowing power and data to be transmitted over a single cable, reducing clutter and setup complexity.

Another standout characteristic is its flexibility. The Pelco IV SE is designed for various mounting options, including wall, ceiling, and pole mounts, making it adaptable for different environments and surveillance needs. The camera features a varifocal lens, allowing users to adjust the field of view to capture images from different distances, thus optimizing surveillance coverage.

Additionally, the Pelco IV SE integrates seamlessly with existing security systems, providing compatibility with various video management software platforms. This interoperability ensures that users can incorporate the camera into their broader security infrastructure without significant disruption.

The device also comes with intelligent video analytics capabilities, such as motion detection and facial recognition, enhancing its functionality. These features allow for proactive monitoring, where alerts can be set up for suspicious activities, ensuring timely responses to potential threats.

With its robust construction, the Pelco IV SE is built to withstand harsh environmental conditions. It adheres to specific IP ratings, indicating its resistance to dust and water, making it an ideal choice for both indoor and outdoor surveillance applications. In summary, the Pelco IV SE is a versatile, high-performance camera that combines advanced imaging capabilities, reliable technology, and extensive adaptability to meet the evolving demands of modern security surveillance.