Pelco 35X, 27X quick start Table B. Switch Settings for SW1, P-Type Control

Page 4

Table B. Switch Settings for SW1, P-Type Control

NOTE: For Coaxitron controls, SW1 is not used; set all switches to OFF. For D-type control systems, refer to Table C.

SPECTRA

 

SWITCH SETTING

 

 

 

 

 

 

ADDRESS

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

 

1

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

2

ON

OFF

OFF

OFF

OFF

3

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

4

ON

ON

OFF

OFF

OFF

5

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

 

6

ON

OFF

ON

OFF

OFF

7

OFF

ON

ON

OFF

OFF

 

 

 

 

 

 

8

ON

ON

ON

OFF

OFF

9

OFF

OFF

OFF

ON

OFF

 

 

 

 

 

 

10

ON

OFF

OFF

ON

OFF

11

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

12

ON

ON

OFF

ON

OFF

13

OFF

OFF

ON

ON

OFF

 

 

 

 

 

 

14

ON

OFF

ON

ON

OFF

15

OFF

ON

ON

ON

OFF

 

 

 

 

 

 

16

ON

ON

ON

ON

OFF

 

 

 

 

 

 

SPECTRA ADDRESS

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

 

SWITCH SETTING

 

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

ON

ON

ON

OFF

OFF

ON

OFF

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

OFF

ON

ON

OFF

ON

ON

ON

ON

OFF

ON

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

ON

ON

OFF

ON

OFF

ON

ON

ON

ON

OFF

ON

ON

OFF

OFF

ON

ON

ON

ON

OFF

ON

ON

ON

OFF

ON

ON

ON

ON

ON

ON

ON

ON

ON

Table C. Switch Settings for SW1, D-Type Control

NOTE: For Coaxitron controls, SW1 is not used; set all switches to OFF. For P-type control systems, refer to Table B.

SPECTRA

 

 

 

SWITCH SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADDRESS SW1-1 SW1-2 SW1-3

SW1-4 SW1-5 SW1-6 SW1-7

SW1-8

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

5

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

6

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

7

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

9

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

10

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

11

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

12

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

13

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

14

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

15

ON

ON

ON

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

SPECTRA

SWITCH SETTING

 

ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8

16

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

17

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

18

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

19

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

20

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

21

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

22

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

23

ON

ON

ON

OFF

ON

OFF

OFF

OFF

24

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

25

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

26

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

27

ON

ON

OFF

ON

ON

OFF

OFF

OFF

28

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

29

ON

OFF

ON

ON

ON

OFF

OFF

OFF

30

OFF

ON

ON

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

4

C3462M (9/09)

Image 4
Contents Spectra IV SL Spectra IV SE Series Dome Systems Installing the Dome Drive Perform one of the following optionsTable A. Switch Settings for SW2 Switch Number RS422RS485, 4-Wire RS485, 2-WireTable B. Switch Settings for SW1, P-Type Control Table C. Switch Settings for SW1, D-Type Control100 111 191 Preset 95 Accessing the Main Menu Press the Spot Monitor keyClick the Go to Preset 95 button. The main menu appears Click the PTZ tabTroubleshooting Problem Possible Causes Suggested ResolutionProduct Warranty and Return Information