6. Functions and Operations
6.1. Input of External HD/VD Signals
As factory setting the camera can be synchronized by external HD/VD signals. The external supplied HD/VD signal should follow the same standard as the camera setting for speed, scanning
and interlace. The signal level must be 4.0
The VD input terminal is used for external trigger signal input in the random trigger modes. If no external HD is connected, the camera will switch to the internal HD.
If no external VD is connected, the camera will continue with its internal VD. For settings, see “7. Mode Setting.”
6.2. Continuous Operation
For applications that not require asynchronous trigger, but run in continuous mode, this mode is used.
To use this mode
Set: | |
| |
| |
Input: | If external synchronizing is used, input HD and VD. |
| Ext. VD to pin 5 on 6 pin connector or pin 7 on 12 pin connector.. |
| Ext. HD to pin 6 |
| 75 Ohm termination is done with |
Refer to | “6.5.Timing Chart” |
For settings, see “7. Mode Setting.”
6.3. External Trigger Mode
This camera has two external trigger modes.
1.Edge
2.Pulse Width Control Mode. (Asynchronous reset and exposure controlled by the low period of the external trigger.)
EDGE Trigger
PULSE Trigger
WIDTH
Exposure
shutter time
Exposure
Readout
Readout
Fig. 6. External trigger modes
The trigger input is AC coupled, and the exposure will start at the first HD pulse after the trigger falling edge. The trigger pulse width should be > 1H to < 1000H.
- 6 -