System Overview (Continued)

Zones and Partitions

The system sensing devices have been assigned to various “zones,” which are specific areas of protection (e.g., front door, kitchen window, etc.).

Zone numbers are displayed at the keypad when an alarm or trouble condition occurs on a sensor.

Partitions (FA168CPS) provide two independent areas of protection, with each partition containing a group of zones that can be armed and disarmed without affecting other zones or users.

Partitioned systems (FA168CPS) can include a common zone area, which is an area shared by users of both partitions (such as a lobby in a building).

Arming, Step-Arming and Disarming Burglary Protection

The system must be armed before the burglary protection can sense intrusions.

To arm your system, enter your security code followed by the desired arming key.

If programmed, you can press the [#] key in place of your security code when arming the system (e.g., instead of entering your 4-digit security code + [3-STAY] to arm the system in STAY mode, you can press [#] + [3-STAY]).

You can use the step-arming key, if programmed, to arm the system, which lets you arm the system in one of three modes by simply pressing the key repeatedly.

To disarm the system, enter your security code then press the [OFF] key.

Alarms

When an alarm occurs, both the keypad and external sounders will sound, and the keypad will display the zone(s) causing the alarm.

If your system is connected to a Central Monitoring Station, an alarm message is also sent. (Delayed Reporting Note: Message reporting is delayed 30 seconds by default to reduce false alarms. If desired, this delay can be removed or can be increased to 45 seconds. See your installer if you want the delay time changed.)

To stop the alarm sounding, simply disarm the system.

Memory of Alarm

When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm (e.g., “FIRE”).

The message remains displayed even after disarming the system, but can be cleared with another “off” sequence.

Function Keys

The “A”, “B”, “C”, and “D” keys on the keypad can be programmed to perform various functions.

Functions include: activate a Panic alarm; arm the system; provide step arming; switch lights on/off; send a message to a pager; display Time/Date; start a Macro.

Scheduling

Your system can be programmed to automatically perform certain functions (e.g., arm the system) at a predetermined time each day.

– 6 –

Page 6
Image 6
Garmin FA168CPS manual Zones and Partitions, Arming, Step-Arming and Disarming Burglary Protection, Alarms, Memory of Alarm

FA168CPS specifications

The Garmin FA168CPS is an advanced navigation device designed primarily for marine use, offering a multitude of features tailored to enhance the user experience on the water. One of its standout characteristics is its high-resolution, sunlight-readable display, which ensures optimal visibility even in bright conditions. The screen is designed to provide clear, detailed maps and graphical data, making navigation easier and more efficient for boaters and sailors alike.

Equipped with GPS and GLONASS technology, the FA168CPS delivers rapid and precise positioning capabilities. This dual-satellite system enhances reliability and coverage, particularly in challenging maritime environments. The device also incorporates a built-in Fishfinder, allowing anglers to locate fish with ease. With advanced sonar capabilities, including CHIRP technology, users can distinguish between different types of fish and underwater structures, significantly increasing their chances of successful fishing trips.

One of the key features of the Garmin FA168CPS is its compatibility with various marine networks. It supports NMEA 2000 for seamless connectivity with other marine devices, allowing users to integrate their navigation system with autopilots, engines, and sensors for streamlined operation. This interoperability enhances situational awareness and greatly improves safety on the water.

Additionally, the FA168CPS comes with preloaded maps and charts, offering comprehensive coverage for coastal and inland waters. The device can also be upgraded with additional Garmin BlueChart g3 maps, providing users with the most up-to-date navigational data, including buoy locations, tidal information, and depth contours.

Among its user-friendly characteristics, the Garmin FA168CPS features intuitive menus and customizable screen layouts, allowing users to personalize their navigation experience. Its robust construction ensures durability in marine environments, making it resistant to water and other harsh conditions. The device is also designed for easy installation, ensuring that boaters can set it up quickly and get right to their adventures.

In summary, the Garmin FA168CPS combines cutting-edge technology with practical features to provide a comprehensive marine navigation solution. From its excellent display and advanced sonar capabilities to its compatibility with marine networks and customizable user interface, this device is an essential tool for anyone looking to navigate the waters with confidence and precision.