CV-L105
6.2.2. Internal Trigger. Shutter mode.
In this mode, the camera does not require an EXT TRIG signal to be issued to the camera. The line rate (scan rate) is generated inside the camera. The camera will operate continuously with its internal trigger.
The scanning interval is equal to the time set by the SCAN parameter.
The exposure time is equal to the Shutter time set by the SHUTTER parameter via
To use this mode: |
|
|
Set function: | Trigger | Internal |
| Mode | SCAN |
| SHUTTER value | 1 µs up to 32.35 ms |
| SCAN value | 151 µs through 32.5 ms |
| Clock, Binning and other functions |
|
Input: | Ext. trigger through the LVDS connector |
|
Important notes on using this mode:-
•It is only recommended to use this mode when there is not change of speed in the object being scanned. If the speed of the object changes, the aspect ratio in the vertical (scanning) direction will change.
Scan interval = SCAN value
Exposure time
= SHUTTER value
Exposure
Data out
LEN
30 MHz 1t=33.3 ns
15 MHz 1t=66.6 ns Value in ( ) is for Binning
Fig. 13. Timing for internal shutter mode
- 11 -