JAI CV-L105 operation manual Trigger modes, Internal Trigger. Scan mode

Page 10

CV-L105

6.2. Trigger modes

Internal Trigger. Scan mode.

The camera will operate continuously with its internal trigger.

The exposure is equal to the scanning time set by the SCAN parameter via RS-232C only. SHUTTER parameter has no meaning here. SCAN value 150 s through 32.5 ms.

Internal Trigger. Shutter mode.

The camera will operate continuously with its internal trigger.

The scanning time is set by the SCAN parameter via RS-232C only.

The exposure is set by the SHUTTER parameter via RS-232C only.

SCAN value 150 s through 32.5 ms. SHUTTER value 1 s through 32.35 ms.

External Trigger. Scan mode.

For every EXT TRIG input the ongoing integration period is terminated and charge is read out. At the same time it starts a new cycle.

The exposure time is therefore dependant of the line rate.

SHUTTER and SCAN parameters has no meaning here.

Trigger pulse width (high period) >4 clk. *) Trigger interval >2120 clk to

External Trigger. Shutter mode.

The exposure time is governed by the low period of the EXT TRIG signal. Exposure starts at the falling edge of the EXT TRIG signal and ends with the rising edge. The integration time is independent of the line rate. SHUTTER and SCAN parameters has no meaning here.

Trigger pulse width (high period) >4 clk. *) Exposure time (low period) >2102 clk to

*) 1 clk is 33.3 ns for 30 MHz clock 1 clk is 66.6 ns for 15 MHz clock

Exposure time =SCANvalue

Exposure

Data out

LEN

Scan interval = SCANvalue

Exposure time

= SHUTTER value

Exposure

Data out

LEN

Trigger Exposure time

Exposure

Data out

LEN

Trigger

Exposure time

Exposure

Data out

Fig. 11. Internal and external trigger modes.

- 9 -

Image 10
Contents CV-L105 Table of Contents CV-L105Standard Composition Main FeaturesGeneral Locations and FunctionsPin Assignment Pin Digital interface connectorGND TXD Pin Hirose connector PowerPin Dsub connector RS-232C RXDVideo output Input and Output CircuitsStrobe LEN Binning select input RS-232C on/off enable/disableTrigger input Pixel rate select inputFunctions and Operations Principle of operationCV-L105 PC with Frame Horizontal Resolution VerticalEncoder Internal Trigger. Scan mode Trigger modesInternal Trigger. Scan mode ScanInternal Trigger. Shutter mode Timing for internal shutter modeExternal Trigger. Scan mode Timing for external trigger scan modeExternal Trigger. Shutter mode ShutterOther functions Configuring the Camera RS-232C control. Communication settingClock Select Trigger ModeShutter/Scan Mode BinningGain and offset adjustment Communication and filesConfiguration via I/F connector and jumpers Potentiometers and jumpers placingExternal Appearance and Dimensions OutlinesSpecifications table SpecificationsSpectral Sensitivity Users Mode Settings Users Modifications Users Record