Adapter EL

All Hasselblad EL models

Exposure Cable EL

All Hasselblad EL models except ELD

The Exposure Cable EL (supplied) should be connected.

Only the single shot function (A or AS mode camera settings) should be set on the camera. Rapid sequence shots are not possible.

Use the Adapter EL (supplied) to provide the necesssary extension beyond the motor hous- ing of the EL models for battery attachment. It is attached to the CFV in the same manner as a battery, and the battery itself is then attached to the adapter as in the illustration.

ELX

For use with 500EL/ELM and 500/553ELX models:

Make an ELX setting.

The Exposure Cable EL (supplied) should be connected.

All exposures times, including the B setting, function correctly without having to alter the “Exposure Time” setting.

Rapid sequence shots are not possible.

Use the Adapter EL (supplied) to provide the necesssary extension beyond the motor hous- ing of the EL models for battery attachment. It is attached to the CFV in the same manner as a battery, and the battery itself is then attached to the adapter as in the illustration.

Pinhole

For use with lenses/cameras with no shutter. Intended primarily for use in a studio en- vironment where complete darkness can be achieved and exposures made accordingly (also useful for ‘light painting’). In this mode the CFV uses the exposure time (as well as other required stages in a capture sequence) set in the Capture Sequence dialog. The back can be triggered either via the START (MENU/EXIT) button or from FlexColor (see later section for full description of Capture Sequence settings procedure).

Flash sync

For use with non-modified 200 series models (together with C-lenses in C-mode), an ArcBody, a FlexBody or view cameras with a Hasselblad adapter.

Make a Flash sync setting.

The Flash sync input cable (supplied) should be connected to the Flash sync in terminal.

All exposures times, including the B setting, function correctly without having to alter the “Exposure Time” setting.

Do not use a winder at rapid sequence setting.

SWC

For use with 903 SWC and 905 SWC models.

• Make an SWC setting.

PLEASE NOTE: Due to the mechanical design of the SWC, pressing the exposure release button too slowly may cause a faulty capture with a magenta cast. Either press the button much more distinctly or alternatively change the setting from SWC to Flash sync and use the flash sync cable to connect the lens to the CFV.

200

For use with modified 202, 203 and 205 models together with F-lenses or CF-lenses in F-mode. (Only these three models can be modified for cable-free compatibility with the CFV. Please contact your Hasselblad dealer for further information)

Make a 200 setting.

A Flash sync input cable should not be used.

All exposures times, including the B setting, function correctly without having to alter the “Exposure Time” setting.

Do not use a winder at rapid sequence setting.

48

Image 48
Contents English, version N T E N T S Congratulations on your new Hasselblad CFV Reproducing skin tones and other difficult colours accurately General Introduction Computer system requirementsBefore you start General overview Menu can be displayed in one of seven different languages Parts, components & control panel buttons Ready light indicator Databus connectorsFireWire connector Battery not supplied Battery retaining catchPowering the digital back To attach a batteryTo remove a battery FireWire connectionShooting/image storage modes Selecting the current mediumCFV can store captured images in three ways See Selecting the Current Storage Medium for detailsUsing compact flash memory cards Working with an ImagebankRemoving a card Working with a Hasselblad ImagebankConnecting to a computer Tethered to a computerRemoving from a computer Shooting with FlexColor runningWhite Bal Media Browse Storage Settings GeneralSee later sections for more comprehensive information Setting the menu language Menu ShortcutsOrganizing your work with batches Navigating media and batchesBatch list Creating new batches Using Instant Approval Architecture Standard Instant Approval workflowReading and changing the approval status Browsing by approval statusSetting the default status Deleting by approval statusBasic image browsing Choosing the current batchZooming in and out Zooming in for more detailThumbnail views Choosing the Preview mode Preview ModesUsing the histogram Full-details modeStandard preview display UnderexposureBattery-saver mode Full-Screen ModeOverexposure indicator Deleting images − general Transferring / Copying images − generalTransferring to a computer Transferring to an ImagebankMenu system overview Navigating the menu systemMenu structure Entries of the main menu Language To set the ISOTo select a preset white balance White balanceMedia To set the browse filter using the menus BrowseStorage To delete a single image Select Main Menu Storage DeletePress  to open the Delete dialog Asked to confirm the delete. Press OKDeleting several images from a batch To delete several images from a selected batchSetting by using the navigator button or ExitButton to cancel Deleting several images from a selected mediumTo delete several images at once Select Main Menu Storage Delete. See alsoFormat To format mediaOK button to cancel Press the Menu buttonDialog. Press  to open the Copy dialog ButBatch To create a new batchDefault APPR. Level To change the default status assigned to each new imageSettings Main Menu Settings User Interface Entries of the User Interface MenuSetting the options under the User Interface menu Proceed as followsMAINMENUSETTINGSCamera Model setting variationsExposure Cable For use with 503 CW modelsAll Hasselblad EL models Shutter Delay Setting Camera model and optionsExposure Time Capture SequenceConnectivity diagram Setting Capture Sequence Press  to select Capture SequencePress  to open the Capture Sequence menu Press either the or button to make an Initial Delay setting Press OK to confirm all the settingsPress Start to set the sequence running This setting Use Selecting an interfaceCamera Disk  About boxMAINMENUSETTINGSDefault To reset all settingsSelect the Main Menu Settings Default entry Press the OK button and then the Exit to returnPortable units TTL function 503CW onlyCleaning the CCD Infrared Filter Basic cleaning procedureCleaning with an E-Wipe Cleaning the housingsEquipment care, Service and Guarantee Technical specifications Image storagePage Sweden Product number Denmark