EverFocus EPTZ3100I user manual

Page 23

3. Connect the cable you detached from base board to the RS485 cable, Power cable and video cable you thread from the wall or ceiling. RS485 cable has to be connected via a terminal block. If you need to connect alarm cable, thread the alarm cable through the second hole. Note: Since video cable and power cable are bare wires, installers have to prepare their own BNC connector and power cord connector.

RS485 cable

Video cable

Power cable

Alarm cable

4. Screw in 4 screws for mounting the bracket base.

23

Image 23
Contents EPTZ3100/EPTZ3100I Table of Contents Positions OSD/AREAS EPTZ3100/EPTZ3100I Camera Setup MenuStructure of the Setup Menu Video SettingsEPTZ3100/3100I Function Setup and Operation Introduction EPTZ3100/EPTZ3100I OverviewPage Push SpecificationsEVF-1 EVF-2 Pelco-P Pelco-D A-Type Plus-D Auto Profile of EPTZ3100/EPTZ3100I FeatureEPTZ3100/EPTZ3100I Base Board Pin # Function EPTZ3100/EPTZ3100I Quick Operation Guide Work with EKB500 Packing List EPTZ3100/EPTZ3100I InstallationEKB500 Keyboard EKB200 USB Controller Video Cable Initial SetupPower Cable Cable NeededAddress Setting 3 4 5 6 7 Protocol/Baud rate ID address Address 128 Transmission Speed Setting Baud Rate Setting Communication Protocol SettingInstallation Requirements Bracket and Speed Dome InstallationEPTZ3100 Dome Camera Wall Mount Simple Installation Page Screw in 4 long screws to fix the bracket to bracket base EPTZ3100 Dome Camera Wall Mount Installation Page Page Page Page Page Page EPTZ3100 Dome Camera Ceiling Mount Installation Page Page Page Pole Mount Adapter Bracket and AdapterIndoor Ceiling Pendent Mount Bracket Indoor Concrete Ceiling Mount Adapter Corner Mount AdapterStructure of the Setup Menu Exposure Video SettingsPage Focus Mode DAY/NIGHT Digital ZoomWhite Balance Wide Dynamic Range DIG. Noise ReduceExit Positions Preset no Position SET Speed Auto Areas OSD/AREASCAM. Title Diagram Directions Press IRIS+ key of keyboard to save and return Show OSD DisplayCamera Status Autopan Auto ModesPage Diagram Preset Tours Pattern Resume to Auto ResumeAuto Flip AlarmPower UP Func 1234 Page Alarm Outputs Motion Detect Info Private Zones Diagram System Info Exit Auto Pan Mode Manual Control ModePosition Setting Tour Mode Set an alarm link Alarm Link to a Position/TourOther Operations Delete an alarm linkJapan Office Head OfficeUSA L.A. Office USA N.Y. Office Europe Office China Office