First Alert K5309-5V2 manual Paging Setup

Page 55

&KDUWV￿RI￿<RXU￿6\VWHP·V￿)HDWXUHV￿

Paging Setup

 

 

 

 

 

Automatically Reports Upon…

 

Sched.

Func. Key

 

 

Pager Phone Number\

open/close

alarm/trouble

zone list

 

 

Pager

Prefix Characters

p1

p2

p1

p2

p1

 

p2

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pagers 3 and 4 apply to FA168CPS.

Schedules: master code + [#] + [6] [4]. (FA168CPS can use schedules 01-16; FA148CP can only use schedules 01-04.)

No.

Event

Device No.

Group No.

Partition††

Start

Stop

Repeat

Random

 

(see list below)

for “01” events:

for “02” events:

for “04-06” events:

Time/

Time/

(1-4)

(yes/no)

 

 

(see device list below)

enter 1-8

enter 1, 2, or 3

Day

Day

 

 

 

 

 

 

 

 

 

 

 

01

 

 

 

 

 

 

 

 

02

 

 

 

 

 

 

 

 

03

 

 

 

 

 

 

 

 

04

 

 

 

 

 

 

 

 

05

 

 

 

 

 

 

 

 

06

 

 

 

 

 

 

 

 

07

 

 

 

 

 

 

 

 

08

 

 

 

 

 

 

 

 

09

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

Events:

00

= clear event

03

= latch key report

06 = auto disarm

 

01

= device on/off

04

= forced STAY arm

07 = display “reminder”

 

02

= user access

05 = forced AWAY arm

†† Partitions apply to the FA168CPS only.

Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week

– 55 –

Image 55
Contents $&36 $&3 $ERXW7KLV0DQXDO Chime Mode Date and Time Functions of the Keypads Entry/Exit DelaysUsing the Keyswitch Disarming and Silencing AlarmsSecurity Codes & Authority Levels Using Device Commands Paging FeatureEvent Logging Procedures Panic Keys 24Macro Key Programming & UsageQwurgxfwlrq \VWHP2YHUYLHZ\VWHP%DVLFV \VWHP2YHUYLHZ&RQWLQXHG 8VLQJWKH9RLFH0HVVDJH&HQWHULI9RLFH.H\SDGLVLQVWDOOHG Phone AccessMessage Center Functions HQHUDO,QIRUPDWLRQ $ERXW7KH.H\SDGV$ERXW7KH.H\SDGV&RQWLQXHG Display Window XQFWLRQVRIWKH.H\SDGVStay Partition QWU\HOD\Partition 2 FA168CPS LW$ODUPV QWU\LWHOD\V&RQWLQXHGKHFNLQJRU2SHQ=RQHV To turn the Voice Status feature on/off #$UPLQJWKH6\VWHP Function Key Arming $UPLQJ&RPPDQGVModes of Arming Press these keys… Keypad Confirms By… Quick Arming6WHS$UPLQJHDWXUH 6LQJOH%XWWRQ$UPLQJKey First Press Second Press Third Press 8VLQJWKH.H\VZLWFK To arm in the Away modeTo arm in the Stay mode 8VLQJWKH.H\VZLWFK8VLQJWKH2@NH\ LVDUPLQJDQG6LOHQFLQJ$ODUPV8VLQJWKH%3$66.H\ \SDVVLQJ3URWHFWLRQ=RQHV4XLFN%\SDVV \SDVVLQJ3URWHFWLRQ =RQHVKLPH0RGH To turn Chime Mode onTo turn Chime Mode off To turn Voice Chime Mode on or offDWHDQG7LPH To activate a Panic Function This Function Sends this signal With This Sounding…3DQLF.H\V 8VLQJ3DQLF.H\V$ERXW0DFUR.H\V 0DFUR.H\3URJUDPPLQJ8VDJHDPSOHRI0DFUR3URJUDPPLQJ 0DFUR.H\3URJUDPPLQJ8VDJHFRQW8VLQJD3URJUDPPHG0DFUR.H\ To Deactivate Devices 8VLQJHYLFH&RPPDQGV$ERXWHYLFH&RPPDQGV To Activate Devices$ERXW$XWRPDWLF3DJLQJ 3DJLQJHDWXUHDWFK.H\3DJLQJ 0DQXDO3DJLQJ$ERXW6HFXULW\&RGHV 6HFXULW\&RGHV$XWKRULW\/HYHOV$XWKRULW\/HYHOHILQLWLRQV +RZWR$VVLJQ8VHU&RGHVDQG$WWULEXWHV $ERXW$FFHVVLQJ3DUWLWLRQV $FFHVVLQJ2WKHU3DUWLWLRQV$&360XOWL3DUWLWLRQ$UPLQJ 8VLQJWKH*R7R&RPPDQG+ ∗ + partition number 0,1,2,3 RPPRQ=RQH2SHUDWLRQ $ERXW6FKHGXOLQJ 6FKHGXOLQJUHDWLQJ6FKHGXOHV +6394291&6 6FKHGXOLQJFRQWLQXHG$ERXWYHQW/RJJLQJ YHQW/RJJLQJ3URFHGXUHV8QGHUVWDQGLQJWKH7\SHRIYHQWLVSOD\HG $ERXW7HVWLQJWKH6\VWHP 7HVWLQJWKH6\VWHP7R%H&RQGXFWHGHHNO\7URXEOH&RQGLWLRQV Check and Battery DisplaysOr Check AlarmFault Rcvr JamLong Rng Trbl Busy-Standby0DLQWDLQLQJRXU6\VWHP Silencing Low Battery Warning Tones at KeypadThis Section Applies only to Residential Systems LUH$ODUP6\VWHP,I,QVWDOOHGKey Pairs Individual KeysLUH$ODUP6\VWHP&RQWLQXHG PHUJHQF\YDFXDWLRQ 4XLFN*XLGHWR%DVLF6\VWHPXQFWLRQV 6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV 6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV FCC Part 5HJXODWRU\6WDWHPHQWVDQGDUQLQJVFederal Communications Commission FCC Part Industry CanadaIndustrie Canada 5HJXODWRU\6WDWHPHQWV&RQWLQXHGFunction Keys Comments KDUWVRIRXU6\VWHP·VHDWXUHVKDUWVRIRXU6\VWHP·VHDWXUHV KDUWVRIRXU6\VWHP·VHDWXUHV Paging Setup List of Output Devices ²1RWHV² ²1RWHV² ²1RWHV² ²1RWHV² OWNER’S Insurance Premium Credit Request Cont $7,21627+,66670 ¬.9l

K5309-5V2 specifications

The First Alert K5309-5V2 is an advanced smoke and carbon monoxide detector that offers essential protection for homes and businesses. This device is designed to enhance safety by detecting smoke and harmful carbon monoxide gases promptly, ensuring timely alerts to prevent emergencies.

One of the standout features of the K5309-5V2 is its clever dual sensor technology. This model utilizes both photoelectric and ionization sensors, which means it can effectively detect different types of fires. Photoelectric sensors are particularly efficient at identifying smoldering fires that produce more smoke, while ionization sensors excel at detecting fast-flaming fires. This combination significantly increases the likelihood of early detection, contributing to quicker response times and reducing the risks associated with fire incidents.

The K5309-5V2 also employs an advanced carbon monoxide detection system. Carbon monoxide is a colorless, odorless gas that can be extremely dangerous, and the K5309-5V2 provides precise detection to alert users in case of an elevated CO level. With a loud 85-decibel alarm, users are ensured that they will hear the alarm even from a distance.

Another notable characteristic of this detector is its easy installation process. The K5309-5V2 can be mounted on walls or ceilings and comes with an easy-to-understand user manual that simplifies setup. The device is powered by batteries, ensuring it remains operational even during power outages.

Moreover, First Alert has incorporated a convenient test and silence button that allows users to routinely test the functionality of the alarm and silence false alarms without removing the battery.

The design of the K5309-5V2 is another merit, featuring a sleek and compact profile that blends well with various home interiors. It is also equipped with a battery- saving mode that extends the life of the battery, minimizing the frequency of replacements.

Overall, the First Alert K5309-5V2 smoke and carbon monoxide detector presents a reliable, dual-sensor solution that prioritizes safety and convenience. Its combination of innovative technologies, ease of use, and effective alarm response makes it a valuable addition to any safety system, helping protect what matters most in any environment.