First Alert K5309-5V2 manual 8VLQJWKH9RLFH0HVVDJH&HQWHULI9RLFH.H\SDGLVLQVWDOOHG, Phone Access

Page 7

6\VWHP￿2YHUYLHZ￿￿&RQWLQXHG￿￿

Phone Access

If included, a Phone Module permits you to access the system via a touch-tone phone, either on-premises or by calling-in when away.

You can receive synthesized voice messages over the telephone regarding the status of the security system.

You can arm and disarm the system and perform most function commands remotely via the telephone, with voice confirmation provided after each command.

Refer to the Phone Access User's Guide supplied with the Phone Module for information regarding the use of this feature.

Paging Feature

If programmed, the system can automatically send certain system condition messages to up to four (FA168CPS) or two (FA148CP) pagers.

The system can also automatically alert a pager if the system has not been disarmed by a certain time (e.g., can let you know a child has not arrived home).

You can also manually send a message to designated pagers.

8VLQJ￿WKH￿9RLFH￿0HVVDJH￿&HQWHU￿￿LI￿9RLFH￿.H\SDG￿LV￿LQVWDOOHG￿￿

The Voice Keypads feature a voice message center that lets you record and playback one message.

The message can be up to 2.5-minutes long

The message remains in the keypad’s memory until a new message is recorded.

The volume control of the message is adjustable.

Refer to the procedures below when using the Message Center functions.

SPEAKER

RECORD KEY

FUNCTION KEYS

 

LEDS

 

 

LCD

 

 

DISPLAY

ARMED

READY

MESSAGE

 

 

 

 

VOLUME

 

 

 

 

KEY

B

4

5 TEST

6BYPASS

PLAY KEY

AND

A

1INSTANTOFFMAX

2 AWAY

3 STAY

UP VOLUME

 

 

RECORD

VOLUME

PLAY

 

C

7 READY

8 CODE

9CHIME

VOLUMEDOWN

D

 

0

#

FUNCTION

 

STATUS

VOICE

FUNCTION

 

*FA560

 

KEY

STATUS

MICROPHONE

VOICE

 

KEY

 

 

KEY

FA560VKP-004-V0

Message Center Functions

 

To…

Press these keys…

Notes…

 

record a

[#] FUNCTION + [0] VOICE + [1] RECORD

The red MESSAGE LED lights.

 

message

 

Message remains in memory

 

 

 

until a new message is recorded.

 

 

 

 

 

 

end

[1] RECORD

The red MESSAGE LED flashes,

 

recording

 

indicating message waiting.

 

play a

[#] FUNCTION + [0] VOICE + [3] PLAY

The recorded message plays and

 

message

 

the red MESSAGE LED turns off.

 

adjust the

[#] FUNCTION + [0] VOICE + [2] VOLUME keys,

Adjusting message volume also

 

volume

then press volume key [3] ↑ (up) or [6] ↓ (down)

adjusts status volume. Volume

 

 

 

cannot be adjusted while playing.

 

 

 

 

 

– 7 –

Image 7
Contents $&36 $&3 $ERXW7KLV0DQXDO Chime Mode Date and Time Functions of the Keypads Entry/Exit DelaysUsing the Keyswitch Disarming and Silencing AlarmsSecurity Codes & Authority Levels Using Device Commands Paging FeatureEvent Logging Procedures Panic Keys 24Macro Key Programming & UsageQwurgxfwlrq \VWHP2YHUYLHZ\VWHP%DVLFV \VWHP2YHUYLHZ&RQWLQXHG 8VLQJWKH9RLFH0HVVDJH&HQWHULI9RLFH.H\SDGLVLQVWDOOHG Phone AccessMessage Center Functions HQHUDO,QIRUPDWLRQ $ERXW7KH.H\SDGV$ERXW7KH.H\SDGV&RQWLQXHG Display Window XQFWLRQVRIWKH.H\SDGVStay Partition QWU\HOD\Partition 2 FA168CPS LW$ODUPV QWU\LWHOD\V&RQWLQXHGKHFNLQJRU2SHQ=RQHV To turn the Voice Status feature on/off #$UPLQJWKH6\VWHP Function Key Arming $UPLQJ&RPPDQGVModes of Arming Press these keys… Keypad Confirms By… Quick Arming6WHS$UPLQJHDWXUH 6LQJOH%XWWRQ$UPLQJKey First Press Second Press Third Press 8VLQJWKH.H\VZLWFK To arm in the Away modeTo arm in the Stay mode 8VLQJWKH.H\VZLWFK8VLQJWKH2@NH\ LVDUPLQJDQG6LOHQFLQJ$ODUPV8VLQJWKH%3$66.H\ \SDVVLQJ3URWHFWLRQ=RQHV4XLFN%\SDVV \SDVVLQJ3URWHFWLRQ =RQHVKLPH0RGH To turn Chime Mode onTo turn Chime Mode off To turn Voice Chime Mode on or offDWHDQG7LPH To activate a Panic Function This Function Sends this signal With This Sounding…3DQLF.H\V 8VLQJ3DQLF.H\V$ERXW0DFUR.H\V 0DFUR.H\3URJUDPPLQJ8VDJHDPSOHRI0DFUR3URJUDPPLQJ 0DFUR.H\3URJUDPPLQJ8VDJHFRQW8VLQJD3URJUDPPHG0DFUR.H\ To Deactivate Devices 8VLQJHYLFH&RPPDQGV$ERXWHYLFH&RPPDQGV To Activate Devices$ERXW$XWRPDWLF3DJLQJ 3DJLQJHDWXUHDWFK.H\3DJLQJ 0DQXDO3DJLQJ$ERXW6HFXULW\&RGHV 6HFXULW\&RGHV$XWKRULW\/HYHOV$XWKRULW\/HYHOHILQLWLRQV +RZWR$VVLJQ8VHU&RGHVDQG$WWULEXWHV $ERXW$FFHVVLQJ3DUWLWLRQV $FFHVVLQJ2WKHU3DUWLWLRQV$&360XOWL3DUWLWLRQ$UPLQJ 8VLQJWKH*R7R&RPPDQG+ ∗ + partition number 0,1,2,3 RPPRQ=RQH2SHUDWLRQ $ERXW6FKHGXOLQJ 6FKHGXOLQJUHDWLQJ6FKHGXOHV +6394291&6 6FKHGXOLQJFRQWLQXHG$ERXWYHQW/RJJLQJ YHQW/RJJLQJ3URFHGXUHV8QGHUVWDQGLQJWKH7\SHRIYHQWLVSOD\HG $ERXW7HVWLQJWKH6\VWHP 7HVWLQJWKH6\VWHP7R%H&RQGXFWHGHHNO\7URXEOH&RQGLWLRQV Check and Battery DisplaysOr Check AlarmFault Rcvr JamLong Rng Trbl Busy-Standby0DLQWDLQLQJRXU6\VWHP Silencing Low Battery Warning Tones at KeypadThis Section Applies only to Residential Systems LUH$ODUP6\VWHP,I,QVWDOOHGKey Pairs Individual KeysLUH$ODUP6\VWHP&RQWLQXHG PHUJHQF\YDFXDWLRQ 4XLFN*XLGHWR%DVLF6\VWHPXQFWLRQV 6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV 6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV FCC Part 5HJXODWRU\6WDWHPHQWVDQGDUQLQJVFederal Communications Commission FCC Part Industry CanadaIndustrie Canada 5HJXODWRU\6WDWHPHQWV&RQWLQXHGFunction Keys Comments KDUWVRIRXU6\VWHP·VHDWXUHVKDUWVRIRXU6\VWHP·VHDWXUHV KDUWVRIRXU6\VWHP·VHDWXUHV Paging Setup List of Output Devices ²1RWHV² ²1RWHV² ²1RWHV² ²1RWHV² OWNER’S Insurance Premium Credit Request Cont $7,21627+,66670 ¬.9l

K5309-5V2 specifications

The First Alert K5309-5V2 is an advanced smoke and carbon monoxide detector that offers essential protection for homes and businesses. This device is designed to enhance safety by detecting smoke and harmful carbon monoxide gases promptly, ensuring timely alerts to prevent emergencies.

One of the standout features of the K5309-5V2 is its clever dual sensor technology. This model utilizes both photoelectric and ionization sensors, which means it can effectively detect different types of fires. Photoelectric sensors are particularly efficient at identifying smoldering fires that produce more smoke, while ionization sensors excel at detecting fast-flaming fires. This combination significantly increases the likelihood of early detection, contributing to quicker response times and reducing the risks associated with fire incidents.

The K5309-5V2 also employs an advanced carbon monoxide detection system. Carbon monoxide is a colorless, odorless gas that can be extremely dangerous, and the K5309-5V2 provides precise detection to alert users in case of an elevated CO level. With a loud 85-decibel alarm, users are ensured that they will hear the alarm even from a distance.

Another notable characteristic of this detector is its easy installation process. The K5309-5V2 can be mounted on walls or ceilings and comes with an easy-to-understand user manual that simplifies setup. The device is powered by batteries, ensuring it remains operational even during power outages.

Moreover, First Alert has incorporated a convenient test and silence button that allows users to routinely test the functionality of the alarm and silence false alarms without removing the battery.

The design of the K5309-5V2 is another merit, featuring a sleek and compact profile that blends well with various home interiors. It is also equipped with a battery- saving mode that extends the life of the battery, minimizing the frequency of replacements.

Overall, the First Alert K5309-5V2 smoke and carbon monoxide detector presents a reliable, dual-sensor solution that prioritizes safety and convenience. Its combination of innovative technologies, ease of use, and effective alarm response makes it a valuable addition to any safety system, helping protect what matters most in any environment.